"manufacturer": "Philio Technology Corp",
|
|
"manufacturerId": "0x013c",
|
|
"label": "PAN30",
|
|
"description": "In-Wall Dual Relay Switch Module",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0001",
|
|
"productId": "0x0077",
|
|
"zwaveAllianceId": [4188, 4194, 4207, 4210, 4213, 4214, 4215, 4251, 4252, 4259]
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"associations": {
|
|
"1": {
|
|
"label": "Lifeline",
|
|
"maxNodes": 5,
|
|
"isLifeline": true
|
|
},
|
|
"2": {
|
|
"label": "Switch EP 1",
|
|
"maxNodes": 5
|
|
},
|
|
"3": {
|
|
"label": "Switch EP 2",
|
|
"maxNodes": 5
|
|
},
|
|
"4": {
|
|
"label": "Meter EP 3",
|
|
"maxNodes": 5
|
|
},
|
|
"5": {
|
|
"label": "Meter EP 4",
|
|
"maxNodes": 5
|
|
}
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Power Reporting Interval",
|
|
"valueSize": 2,
|
|
"unit": "5 seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 720,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "kWh Reporting Interval",
|
|
"valueSize": 2,
|
|
"unit": "10 minutes",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 6,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Power Reporting Threshold: Limit",
|
|
"valueSize": 2,
|
|
"unit": ".01 A",
|
|
"minValue": 10,
|
|
"maxValue": 750,
|
|
"defaultValue": 750
|
|
},
|
|
{
|
|
"#": "7",
|
|
"label": "Power Reporting Threshold: Change",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 4,
|
|
"defaultValue": 1,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "5%",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "10%",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "15%",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "20%",
|
|
"value": 4
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "kWh Reporting Threshold: Limit",
|
|
"valueSize": 2,
|
|
"unit": "kWh",
|
|
"minValue": 1,
|
|
"maxValue": 10000,
|
|
"defaultValue": 10000
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "External Switch Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Edge mode",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Pulse mode",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Edge-Toggle mode",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "6",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on"
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode",
|
|
"exclusion": "1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.\n3. Node ID has been excluded",
|
|
"reset": "1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.\n2. Within 1 second, press On/Off button again for 5 seconds.\n3. IDs are excluded",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4188/PAN30%20manual-20210602.pdf"
|
|
}
|
|
}
|