{ "manufacturer": "Philio Technology Corp", "manufacturerId": "0x013c", "label": "PAN30", "description": "In-Wall Dual Relay Switch Module", "devices": [ { "productType": "0x0001", "productId": "0x0077", "zwaveAllianceId": [4188, 4194, 4207, 4210, 4213, 4214, 4215, 4251, 4252, 4259] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 5, "isLifeline": true }, "2": { "label": "Switch EP 1", "maxNodes": 5 }, "3": { "label": "Switch EP 2", "maxNodes": 5 }, "4": { "label": "Meter EP 3", "maxNodes": 5 }, "5": { "label": "Meter EP 4", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "label": "Power Reporting Interval", "valueSize": 2, "unit": "5 seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 720, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "2", "label": "kWh Reporting Interval", "valueSize": 2, "unit": "10 minutes", "minValue": 0, "maxValue": 32767, "defaultValue": 6, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "3", "label": "Power Reporting Threshold: Limit", "valueSize": 2, "unit": ".01 A", "minValue": 10, "maxValue": 750, "defaultValue": 750 }, { "#": "7", "label": "Power Reporting Threshold: Change", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 4, "defaultValue": 1, "options": [ { "label": "Disable", "value": 0 }, { "label": "5%", "value": 1 }, { "label": "10%", "value": 2 }, { "label": "15%", "value": 3 }, { "label": "20%", "value": 4 } ] }, { "#": "4", "label": "kWh Reporting Threshold: Limit", "valueSize": 2, "unit": "kWh", "minValue": 1, "maxValue": 10000, "defaultValue": 10000 }, { "#": "5", "label": "External Switch Mode", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Edge mode", "value": 1 }, { "label": "Pulse mode", "value": 2 }, { "label": "Edge-Toggle mode", "value": 3 } ] }, { "#": "6", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on" } ], "metadata": { "inclusion": "1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode", "exclusion": "1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.\n3. Node ID has been excluded", "reset": "1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.\n2. Within 1 second, press On/Off button again for 5 seconds.\n3. IDs are excluded", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4188/PAN30%20manual-20210602.pdf" } }