zwave-js/.config-db/devices/0x013c/pan30.json
2025-01-10 22:05:04 -08:00

152 lines
3.2 KiB
JSON

{
"manufacturer": "Philio Technology Corp",
"manufacturerId": "0x013c",
"label": "PAN30",
"description": "In-Wall Dual Relay Switch Module",
"devices": [
{
"productType": "0x0001",
"productId": "0x0077",
"zwaveAllianceId": [4188, 4194, 4207, 4210, 4213, 4214, 4215, 4251, 4252, 4259]
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
},
"2": {
"label": "Switch EP 1",
"maxNodes": 5
},
"3": {
"label": "Switch EP 2",
"maxNodes": 5
},
"4": {
"label": "Meter EP 3",
"maxNodes": 5
},
"5": {
"label": "Meter EP 4",
"maxNodes": 5
}
},
"paramInformation": [
{
"#": "1",
"label": "Power Reporting Interval",
"valueSize": 2,
"unit": "5 seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 720,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "2",
"label": "kWh Reporting Interval",
"valueSize": 2,
"unit": "10 minutes",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 6,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "3",
"label": "Power Reporting Threshold: Limit",
"valueSize": 2,
"unit": ".01 A",
"minValue": 10,
"maxValue": 750,
"defaultValue": 750
},
{
"#": "7",
"label": "Power Reporting Threshold: Change",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 4,
"defaultValue": 1,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "5%",
"value": 1
},
{
"label": "10%",
"value": 2
},
{
"label": "15%",
"value": 3
},
{
"label": "20%",
"value": 4
}
]
},
{
"#": "4",
"label": "kWh Reporting Threshold: Limit",
"valueSize": 2,
"unit": "kWh",
"minValue": 1,
"maxValue": 10000,
"defaultValue": 10000
},
{
"#": "5",
"label": "External Switch Mode",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Edge mode",
"value": 1
},
{
"label": "Pulse mode",
"value": 2
},
{
"label": "Edge-Toggle mode",
"value": 3
}
]
},
{
"#": "6",
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on"
}
],
"metadata": {
"inclusion": "1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode",
"exclusion": "1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.\n3. Node ID has been excluded",
"reset": "1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.\n2. Within 1 second, press On/Off button again for 5 seconds.\n3. IDs are excluded",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4188/PAN30%20manual-20210602.pdf"
}
}