55 lines
1.7 KiB
JSON
55 lines
1.7 KiB
JSON
{
|
|
"manufacturer": "Everspring",
|
|
"manufacturerId": "0x0060",
|
|
"label": "SP815",
|
|
"description": "PET IMMUNE PIR MOTION DETECTOR",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0001",
|
|
"productId": "0x0004",
|
|
"zwaveAllianceId": 3366
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Temperature and Humidity Auto Report Period Setting",
|
|
"description": "Minutes",
|
|
"valueSize": 2,
|
|
"unit": "minutes",
|
|
"minValue": 0,
|
|
"maxValue": 255,
|
|
"defaultValue": 30
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Re-Trigger Interval Setting (For PIR Sensor Only)",
|
|
"description": "Seconds",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 15,
|
|
"defaultValue": 15
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Trigger Off Interval Setting",
|
|
"description": "Seconds",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 255,
|
|
"defaultValue": 15
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "1. Put the Z-Wave Controller into inclusion mode.\n2. Press the learn key 3 times within 1.5 seconds to put the unit into inclusion mode.",
|
|
"exclusion": "1. Put the Z-Wave Controller into exclusion mode.\n2. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode.",
|
|
"reset": "1. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode.\n2. Within 1 second of step 1, press the learn key again and hold for 5 seconds.\n3. Node ID is excluded. The device reverts to factory default state.\n(This procedure should only be used when the controller is inoperable.)",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3366/SP815%20user%20manual_05102019-A501112752R01.pdf"
|
|
}
|
|
}
|