{ "manufacturer": "Everspring", "manufacturerId": "0x0060", "label": "SP815", "description": "PET IMMUNE PIR MOTION DETECTOR", "devices": [ { "productType": "0x0001", "productId": "0x0004", "zwaveAllianceId": 3366 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Temperature and Humidity Auto Report Period Setting", "description": "Minutes", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 255, "defaultValue": 30 }, { "#": "2", "label": "Re-Trigger Interval Setting (For PIR Sensor Only)", "description": "Seconds", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 15, "defaultValue": 15 }, { "#": "3", "label": "Trigger Off Interval Setting", "description": "Seconds", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 255, "defaultValue": 15 } ], "metadata": { "inclusion": "1. Put the Z-Wave Controller into inclusion mode.\n2. Press the learn key 3 times within 1.5 seconds to put the unit into inclusion mode.", "exclusion": "1. Put the Z-Wave Controller into exclusion mode.\n2. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode.", "reset": "1. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode.\n2. Within 1 second of step 1, press the learn key again and hold for 5 seconds.\n3. Node ID is excluded. The device reverts to factory default state.\n(This procedure should only be used when the controller is inoperable.)", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3366/SP815%20user%20manual_05102019-A501112752R01.pdf" } }