"manufacturer": "Everspring",
"manufacturerId": "0x0060",
"label": "SP815",
"description": "PET IMMUNE PIR MOTION DETECTOR",
"devices": [
{
"productType": "0x0001",
"productId": "0x0004",
"zwaveAllianceId": 3366
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Temperature and Humidity Auto Report Period Setting",
"description": "Minutes",
"valueSize": 2,
"unit": "minutes",
"minValue": 0,
"maxValue": 255,
"defaultValue": 30
},
{
"#": "2",
"label": "Re-Trigger Interval Setting (For PIR Sensor Only)",
"description": "Seconds",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 15,
"defaultValue": 15
},
{
"#": "3",
"label": "Trigger Off Interval Setting",
"description": "Seconds",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 255,
"defaultValue": 15
}
],
"metadata": {
"inclusion": "1. Put the Z-Wave Controller into inclusion mode.\n2. Press the learn key 3 times within 1.5 seconds to put the unit into inclusion mode.",
"exclusion": "1. Put the Z-Wave Controller into exclusion mode.\n2. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode.",
"reset": "1. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode.\n2. Within 1 second of step 1, press the learn key again and hold for 5 seconds.\n3. Node ID is excluded. The device reverts to factory default state.\n(This procedure should only be used when the controller is inoperable.)",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3366/SP815%20user%20manual_05102019-A501112752R01.pdf"
}
}