zwave-js/.config-db/devices/0x0371/zwa008.json
2025-01-10 22:05:04 -08:00

126 lines
3.2 KiB
JSON

{
"manufacturer": "Aeotec Ltd.",
"manufacturerId": "0x0371",
"label": "ZWA008",
"description": "Door/Window Sensor 7",
"devices": [
{
"productType": "0x0000",
"productId": "0x0007",
"zwaveAllianceId": 3472
},
{
"productType": "0x0002",
"productId": "0x0007"
},
{
"productType": "0x0102",
"productId": "0x0007",
"zwaveAllianceId": 3574
},
{
"productType": "0x0202",
"productId": "0x0007",
"zwaveAllianceId": 3573
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
},
"2": {
"label": "Group 2",
"maxNodes": 5
},
"3": {
"label": "Group 3",
"maxNodes": 5
},
"4": {
"label": "Group 4",
"maxNodes": 5
}
},
"paramInformation": [
{
"#": "1",
"$import": "~/0x0086/templates/aeotec_template.json#sensor_operation_mode"
},
{
"#": "2",
"$import": "~/0x0086/templates/aeotec_template.json#invert_state_report"
},
{
"#": "3[0x02]",
"$import": "~/0x0086/templates/aeotec_template.json#led_indicator_open"
},
{
"#": "3[0x04]",
"$import": "~/0x0086/templates/aeotec_template.json#led_indicator_wake"
},
{
"#": "3[0x10]",
"$import": "~/0x0086/templates/aeotec_template.json#led_indicator_tamper"
},
{
"#": "4",
"$import": "~/0x0086/templates/aeotec_template.json#range_test_double_click"
},
{
"#": "5",
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_trigger"
},
{
"#": "6",
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_command_type"
},
{
"#": "7",
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_basic_set_on"
},
{
"#": "8",
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_basic_set_off"
},
{
"#": "9",
"$import": "~/0x0086/templates/aeotec_template.json#time_delay_on"
},
{
"#": "10",
"$import": "~/0x0086/templates/aeotec_template.json#time_delay_off"
},
{
"#": "11",
"$import": "~/0x0086/templates/aeotec_template.json#time_delay_tamper"
},
{
"#": "12",
"$import": "~/0x0086/templates/aeotec_template.json#report_on_tamper_cancel"
},
{
"#": "13",
"$import": "~/0x0086/templates/aeotec_template.json#central_scene_functionality"
},
{
"#": "14",
"$import": "~/0x0086/templates/aeotec_template.json#tilt_sensor"
},
{
"#": "15",
"$import": "~/0x0086/templates/aeotec_template.json#tilt_sensor_sensitivity"
}
],
"metadata": {
"inclusion": "Triple clicking the tamper button includes (adds) the device",
"exclusion": "Triple clicking the tamper button excludes (removes) the device",
"reset": "This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.\nOnce Cover is removed and tamper switch is tripped, push the tamper for 5 seconds until red LED blinks. Then release tamper and push it again for 5 seconds until LED blinks",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3472/User%20manual%20-%20Aeotec%20Door%20Window%20Sensor%207%20ZWA008.pdf"
}
}