{ "manufacturer": "Aeotec Ltd.", "manufacturerId": "0x0371", "label": "ZWA008", "description": "Door/Window Sensor 7", "devices": [ { "productType": "0x0000", "productId": "0x0007", "zwaveAllianceId": 3472 }, { "productType": "0x0002", "productId": "0x0007" }, { "productType": "0x0102", "productId": "0x0007", "zwaveAllianceId": 3574 }, { "productType": "0x0202", "productId": "0x0007", "zwaveAllianceId": 3573 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 5, "isLifeline": true }, "2": { "label": "Group 2", "maxNodes": 5 }, "3": { "label": "Group 3", "maxNodes": 5 }, "4": { "label": "Group 4", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "$import": "~/0x0086/templates/aeotec_template.json#sensor_operation_mode" }, { "#": "2", "$import": "~/0x0086/templates/aeotec_template.json#invert_state_report" }, { "#": "3[0x02]", "$import": "~/0x0086/templates/aeotec_template.json#led_indicator_open" }, { "#": "3[0x04]", "$import": "~/0x0086/templates/aeotec_template.json#led_indicator_wake" }, { "#": "3[0x10]", "$import": "~/0x0086/templates/aeotec_template.json#led_indicator_tamper" }, { "#": "4", "$import": "~/0x0086/templates/aeotec_template.json#range_test_double_click" }, { "#": "5", "$import": "~/0x0086/templates/aeotec_template.json#association_group_2_trigger" }, { "#": "6", "$import": "~/0x0086/templates/aeotec_template.json#association_group_2_command_type" }, { "#": "7", "$import": "~/0x0086/templates/aeotec_template.json#association_group_2_basic_set_on" }, { "#": "8", "$import": "~/0x0086/templates/aeotec_template.json#association_group_2_basic_set_off" }, { "#": "9", "$import": "~/0x0086/templates/aeotec_template.json#time_delay_on" }, { "#": "10", "$import": "~/0x0086/templates/aeotec_template.json#time_delay_off" }, { "#": "11", "$import": "~/0x0086/templates/aeotec_template.json#time_delay_tamper" }, { "#": "12", "$import": "~/0x0086/templates/aeotec_template.json#report_on_tamper_cancel" }, { "#": "13", "$import": "~/0x0086/templates/aeotec_template.json#central_scene_functionality" }, { "#": "14", "$import": "~/0x0086/templates/aeotec_template.json#tilt_sensor" }, { "#": "15", "$import": "~/0x0086/templates/aeotec_template.json#tilt_sensor_sensitivity" } ], "metadata": { "inclusion": "Triple clicking the tamper button includes (adds) the device", "exclusion": "Triple clicking the tamper button excludes (removes) the device", "reset": "This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.\nOnce Cover is removed and tamper switch is tripped, push the tamper for 5 seconds until red LED blinks. Then release tamper and push it again for 5 seconds until LED blinks", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3472/User%20manual%20-%20Aeotec%20Door%20Window%20Sensor%207%20ZWA008.pdf" } }