zwave-js/.config-db/devices/0x0312/mp21zp_mp31zp.json
2025-01-10 22:05:04 -08:00

82 lines
3.3 KiB
JSON

{
"manufacturer": "Minoston",
"manufacturerId": "0x0312",
"label": "MP21ZP / MP31ZP",
"description": "Mini Plug with Power Meter",
"devices": [
{
"productType": "0xff00",
"productId": "0xff0e",
"zwaveAllianceId": 4247
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"$import": "templates/minoston_template.json#led_indicator_four_options_inverted"
},
{
"#": "9",
"$if": "firmwareVersion >= 1.10.1",
"$import": "templates/minoston_template.json#led_indicator_brightness"
},
{
"#": "2",
"$import": "templates/minoston_template.json#auto_off_timer"
},
{
"#": "3",
"$import": "templates/minoston_template.json#auto_on_timer"
},
{
"#": "4",
"$import": "~/templates/master_template.json#state_after_power_failure_prev_off_on"
},
{
"#": "10",
"$if": "firmwareVersion >= 1.11.1",
"$import": "templates/minoston_template.json#power_reporting"
},
{
"#": "5",
"$import": "templates/minoston_template.json#power_reporting_threshold"
},
{
"#": "6",
"$import": "templates/minoston_template.json#power_reporting_interval"
},
{
"#": "11",
"$if": "firmwareVersion >= 1.11.1",
"$import": "templates/minoston_template.json#current_reporting"
},
{
"#": "7",
"$import": "templates/minoston_template.json#current_reporting_threshold"
},
{
"#": "12",
"$if": "firmwareVersion >= 1.11.1",
"$import": "templates/minoston_template.json#current_reporting_interval"
},
{
"#": "8",
"$import": "templates/minoston_template.json#energy_reporting_threshold"
},
{
"#": "13",
"$if": "firmwareVersion >= 1.11.1",
"$import": "templates/minoston_template.json#voltage_reporting_interval"
}
],
"metadata": {
"inclusion": "ADD or Remove the MP21ZP from the existing Z-Wave home control network with your primary controller.\n---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.\n---When prompted by your primary controller, click the PROG button Three times in one second.\nInclude MP21ZP to/from a Z-Wave Gateway with supporting Security.The MP21ZP can support the Primary Controller that implemented the\nNotice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by\nZ-WaveTM Controller means “Remove” or “Exclusion”",
"exclusion": "ADD or Remove the MP21ZP from the existing Z-Wave home control network with your primary controller.\n---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.\n---When prompted by your primary controller, click the PROG button Three times in one second.\nInclude MP21ZP to/from a Z-Wave Gateway with supporting Security.The MP21ZP can support the Primary Controller that implemented the\nNotice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by\nZ-WaveTM Controller means “Remove” or “Exclusion”",
"reset": "Press the button twice quickly and then press and hold the button 10S.device will reset\n(Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable)",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4247/MP21ZP-manual-20210722.pdf"
}
}