zwave-js/.config-db/devices/0x027a/zen26.json
2025-01-10 22:05:04 -08:00

128 lines
3.7 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

{
"manufacturer": "Zooz",
"manufacturerId": "0x027a",
"label": "ZEN26",
"description": "Z-Wave Plus S2 ON/OFF Switch",
"devices": [
{
"productType": "0xa000",
"productId": "0xa001"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 1,
"isLifeline": true
},
"2": {
"label": "On/Off Control",
"maxNodes": 5
}
},
"paramInformation": [
{
"#": "1",
"$if": "firmwareVersion <= 2.2",
"$import": "~/templates/master_template.json#orientation"
},
{
"#": "1",
"$if": "firmwareVersion >= 2.3",
"$import": "~/templates/master_template.json#orientation_momentary"
},
{
"#": "2",
"$import": "~/templates/master_template.json#led_indicator_four_options"
},
{
"#": "3",
"$if": "firmwareVersion <= 1.255",
"label": "Auto Turn-Off Timer Duration",
"description": "Set the number of seconds to automatically turn off switch once it has been turned on (0 to disable).",
"valueSize": 2,
"minValue": 0,
"maxValue": 32767,
"defaultValue": 60
},
{
"#": "3",
"$if": "firmwareVersion >= 2.0",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Auto Turn-Off Timer"
},
{
"#": "4",
"$if": "firmwareVersion >= 2.0",
"$import": "templates/zooz_template.json#auto_off_timer_duration"
},
{
"#": "5",
"$if": "firmwareVersion >= 2.0",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Auto Turn-On Timer"
},
{
"#": "6",
"$if": "firmwareVersion >= 2.0",
"$import": "templates/zooz_template.json#auto_on_timer_duration"
},
{
"#": "7[0x01]",
"$if": "firmwareVersion >= 2.0",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Control Group 2 with Physical Switch",
"defaultValue": 1
},
{
"#": "7[0x02]",
"$if": "firmwareVersion >= 2.0",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Control Group 2 with Connected 3-Way Switch",
"defaultValue": 1
},
{
"#": "7[0x04]",
"$if": "firmwareVersion >= 2.0",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Control Group 2 with Z-Wave Commands",
"defaultValue": 1
},
{
"#": "7[0x08]",
"$if": "firmwareVersion >= 2.0",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Control Group 2 with On/Off Timers",
"defaultValue": 1
},
{
"#": "8",
"$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev"
},
{
"#": "10",
"$if": "firmwareVersion >= 2.0",
"$import": "templates/zooz_template.json#enable_scene_control"
},
{
"#": "11",
"$if": "firmwareVersion >= 2.0",
"$import": "~/templates/master_template.json#smart_switch_mode_0-2"
},
{
"#": "13",
"$if": "firmwareVersion >= 2.2",
"$import": "templates/zooz_template.json#smart_switch_mode_reporting"
}
],
"metadata": {
"inclusion": "1. Initiate inclusion mode on the Z-Wave hub.\n2. Tap the upper paddle of the switch 3 times quickly. The LED indicators will blink to signal communication and remain on for 2 seconds to confirm inclusion",
"exclusion": "1. Initiate exclusion mode on the Z-Wave hub.\n2. Tap the lower paddle on the switch 3 times quickly\n3. Your hub will confirm exclusion and the device will disappear from your controller's device list",
"reset": "1. Tap-tap-tapnhold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset.",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3147/zooz-z-wave-plus-s2-on-off-switch-zen26-manual.pdf"
}
}