{ "manufacturer": "Zooz", "manufacturerId": "0x027a", "label": "ZEN26", "description": "Z-Wave Plus S2 ON/OFF Switch", "devices": [ { "productType": "0xa000", "productId": "0xa001" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true }, "2": { "label": "On/Off Control", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "$if": "firmwareVersion <= 2.2", "$import": "~/templates/master_template.json#orientation" }, { "#": "1", "$if": "firmwareVersion >= 2.3", "$import": "~/templates/master_template.json#orientation_momentary" }, { "#": "2", "$import": "~/templates/master_template.json#led_indicator_four_options" }, { "#": "3", "$if": "firmwareVersion <= 1.255", "label": "Auto Turn-Off Timer Duration", "description": "Set the number of seconds to automatically turn off switch once it has been turned on (0 to disable).", "valueSize": 2, "minValue": 0, "maxValue": 32767, "defaultValue": 60 }, { "#": "3", "$if": "firmwareVersion >= 2.0", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Auto Turn-Off Timer" }, { "#": "4", "$if": "firmwareVersion >= 2.0", "$import": "templates/zooz_template.json#auto_off_timer_duration" }, { "#": "5", "$if": "firmwareVersion >= 2.0", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Auto Turn-On Timer" }, { "#": "6", "$if": "firmwareVersion >= 2.0", "$import": "templates/zooz_template.json#auto_on_timer_duration" }, { "#": "7[0x01]", "$if": "firmwareVersion >= 2.0", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Control Group 2 with Physical Switch", "defaultValue": 1 }, { "#": "7[0x02]", "$if": "firmwareVersion >= 2.0", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Control Group 2 with Connected 3-Way Switch", "defaultValue": 1 }, { "#": "7[0x04]", "$if": "firmwareVersion >= 2.0", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Control Group 2 with Z-Wave Commands", "defaultValue": 1 }, { "#": "7[0x08]", "$if": "firmwareVersion >= 2.0", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Control Group 2 with On/Off Timers", "defaultValue": 1 }, { "#": "8", "$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev" }, { "#": "10", "$if": "firmwareVersion >= 2.0", "$import": "templates/zooz_template.json#enable_scene_control" }, { "#": "11", "$if": "firmwareVersion >= 2.0", "$import": "~/templates/master_template.json#smart_switch_mode_0-2" }, { "#": "13", "$if": "firmwareVersion >= 2.2", "$import": "templates/zooz_template.json#smart_switch_mode_reporting" } ], "metadata": { "inclusion": "1. Initiate inclusion mode on the Z-Wave hub.\n2. Tap the upper paddle of the switch 3 times quickly. The LED indicators will blink to signal communication and remain on for 2 seconds to confirm inclusion", "exclusion": "1. Initiate exclusion mode on the Z-Wave hub.\n2. Tap the lower paddle on the switch 3 times quickly\n3. Your hub will confirm exclusion and the device will disappear from your controller's device list", "reset": "1. Tap-tap-tap’n’hold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3147/zooz-z-wave-plus-s2-on-off-switch-zen26-manual.pdf" } }