"manufacturer": "Climax Technology, Ltd.",
|
||
"manufacturerId": "0x018e",
|
||
"label": "S-2ZW",
|
||
"description": "Shutter Control",
|
||
"devices": [
|
||
{
|
||
"productType": "0x0004",
|
||
"productId": "0x0005",
|
||
"zwaveAllianceId": 3246
|
||
}
|
||
],
|
||
"firmwareVersion": {
|
||
"min": "0.0",
|
||
"max": "255.255"
|
||
},
|
||
"paramInformation": [
|
||
{
|
||
"#": "1",
|
||
"label": "Up Time Setting",
|
||
"valueSize": 2,
|
||
"unit": "seconds",
|
||
"minValue": 0,
|
||
"maxValue": 255,
|
||
"defaultValue": 240
|
||
},
|
||
{
|
||
"#": "2",
|
||
"label": "Close Time Setting",
|
||
"valueSize": 2,
|
||
"unit": "seconds",
|
||
"minValue": 0,
|
||
"maxValue": 255,
|
||
"defaultValue": 240
|
||
},
|
||
{
|
||
"#": "3",
|
||
"label": "Current Position",
|
||
"description": "The ranges from 0% to 99%",
|
||
"valueSize": 2,
|
||
"minValue": 0,
|
||
"maxValue": 99,
|
||
"defaultValue": 99
|
||
}
|
||
],
|
||
"metadata": {
|
||
"inclusion": "This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.\n1. Connect the power to Shutter Control (see manual’s Installation).\n2. Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).\n3. Within 1.5 seconds, press the Function Button 3 times.\n4. Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding process.\n5. If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).",
|
||
"exclusion": "The device must be removed from existing Z-Wave network before being added into another.\n1. Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).\n2. Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-Wave network.",
|
||
"reset": "(Only use factory reset when network Control Panel/Gateway is missing or inoperable).\nFactory resetting the device will restore it to factory default settings (i.e. excluded from Z-Wave network). Please use the reset procedure only when the primary controller is missing or inoperable.\n\nPress and hold the Function Button of the device for 10 seconds to factory reset.",
|
||
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3246/SCM_2_ZW.pdf"
|
||
}
|
||
}
|