zwave-js/.config-db/devices/0x018e/s-2zw.json

53 lines
2.5 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Climax Technology, Ltd.",
"manufacturerId": "0x018e",
"label": "S-2ZW",
"description": "Shutter Control",
"devices": [
{
"productType": "0x0004",
"productId": "0x0005",
"zwaveAllianceId": 3246
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Up Time Setting",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 255,
"defaultValue": 240
},
{
"#": "2",
"label": "Close Time Setting",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 255,
"defaultValue": 240
},
{
"#": "3",
"label": "Current Position",
"description": "The ranges from 0% to 99%",
"valueSize": 2,
"minValue": 0,
"maxValue": 99,
"defaultValue": 99
}
],
"metadata": {
"inclusion": "This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.\n1. Connect the power to Shutter Control (see manuals Installation).\n2. Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).\n3. Within 1.5 seconds, press the Function Button 3 times.\n4. Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding process.\n5. If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).",
"exclusion": "The device must be removed from existing Z-Wave network before being added into another.\n1. Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).\n2. Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-Wave network.",
"reset": "(Only use factory reset when network Control Panel/Gateway is missing or inoperable).\nFactory resetting the device will restore it to factory default settings (i.e. excluded from Z-Wave network). Please use the reset procedure only when the primary controller is missing or inoperable.\n\nPress and hold the Function Button of the device for 10 seconds to factory reset.",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3246/SCM_2_ZW.pdf"
}
}