zwave-js/.config-db/devices/0x0149/c7.json
2025-01-10 22:05:04 -08:00

376 lines
7 KiB
JSON

{
"manufacturer": "wiDom",
"manufacturerId": "0x0149",
"label": "C7",
"description": "Energy Driven Switch",
"devices": [
{
"productType": "0x0004",
"productId": "0x0009"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "21",
"label": "Output Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Direct load control or normally open relay",
"value": 0
},
{
"label": "Normally closed relay",
"value": 1
}
]
},
{
"#": "23",
"$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev",
"defaultValue": 0
},
{
"#": "31",
"label": "Auto-Off Timer",
"valueSize": 4,
"unit": "0.1 seconds",
"minValue": 0,
"maxValue": 360000,
"defaultValue": 0,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "32",
"label": "Auto-On Timer",
"valueSize": 4,
"unit": "0.1 seconds",
"minValue": 0,
"maxValue": 360000,
"defaultValue": 0,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "40",
"label": "Up Power: Integrated Relay Reaction",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Turn off",
"value": 0
},
{
"label": "Turn on",
"value": 1
}
]
},
{
"#": "41",
"label": "Down Power: Integrated Relay Reaction",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Turn off",
"value": 0
},
{
"label": "Turn on",
"value": 1
}
]
},
{
"#": "42",
"label": "Meter Type",
"description": "Defines how consumed (positive) and produced (negative) energy is treated",
"valueSize": 1,
"defaultValue": 3,
"allowManualEntry": false,
"options": [
{
"label": "Measure consumed and produced energy",
"value": 0
},
{
"label": "Measure consumed energy only, ignore produced energy",
"value": 1
},
{
"label": "Measure produced energy only, ignore consumed energy",
"value": 2
},
{
"label": "Energy is only consumed",
"value": 3
},
{
"label": "Energy is only produced",
"value": 4
}
]
},
{
"#": "43",
"label": "Current Transformer Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Standard type",
"value": 1
},
{
"label": "Type 2 version",
"value": 2
}
]
},
{
"#": "44",
"label": "Up Power: Value Sent to Association Groups",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 0,
"options": [
{
"label": "Off",
"value": 0
},
{
"label": "On (0xff)",
"value": 100
}
]
},
{
"#": "45",
"label": "Up Power: Value Sent to Association Groups",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 100,
"options": [
{
"label": "Off",
"value": 0
},
{
"label": "On (0xff)",
"value": 100
}
]
},
{
"#": "46",
"label": "Over Voltage Threshold",
"valueSize": 2,
"unit": "0.1 V",
"minValue": 900,
"maxValue": 2530,
"defaultValue": 2530
},
{
"#": "47",
"label": "Down Voltage Threshold",
"valueSize": 2,
"unit": "0.1 V",
"minValue": 900,
"maxValue": 2530,
"defaultValue": 2070
},
{
"#": "50",
"label": "Up Power: Threshold",
"valueSize": 4,
"unit": "W",
"minValue": 0,
"maxValue": 100000,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "51",
"label": "Up Power: Energy Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Consumed",
"value": 0
},
{
"label": "Produced",
"value": 1
}
]
},
{
"#": "52",
"label": "Up Power: First Timeout",
"description": "After this time above the Up Power threshold, an Up Power event occurs",
"valueSize": 2,
"unit": "seconds",
"minValue": 2,
"maxValue": 7200,
"defaultValue": 30
},
{
"#": "53",
"label": "Up Power: Next Timeout",
"description": "After this time above the Up Power threshold, further Up Power events occur",
"valueSize": 2,
"unit": "seconds",
"minValue": 2,
"maxValue": 7200,
"defaultValue": 5
},
{
"#": "54",
"label": "Down Power: Threshold",
"valueSize": 4,
"unit": "W",
"minValue": 0,
"maxValue": 100000,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "55",
"label": "Down Power: Energy Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Consumed",
"value": 0
},
{
"label": "Produced",
"value": 1
}
]
},
{
"#": "56",
"label": "Down Power: First Timeout",
"description": "After this time below the Down Power threshold, an Down Power event occurs",
"valueSize": 2,
"unit": "seconds",
"minValue": 2,
"maxValue": 7200,
"defaultValue": 30
},
{
"#": "57",
"label": "Down Power: Next Timeout",
"description": "After this time below the Down Power threshold, further Down Power events occur",
"valueSize": 2,
"unit": "seconds",
"minValue": 2,
"maxValue": 7200,
"defaultValue": 5
},
{
"#": "58",
"label": "Up/Down Power: Protection Time",
"description": "How long to wait before Up/Down Power Events can be triggered again",
"valueSize": 2,
"unit": "seconds",
"minValue": 2,
"maxValue": 3600,
"defaultValue": 60
},
{
"#": "71",
"label": "Meter Report Interval",
"valueSize": 1,
"unit": "minutes",
"minValue": 1,
"maxValue": 120,
"defaultValue": 10
},
{
"#": "75",
"label": "Power Change Report Threshold",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 100,
"defaultValue": 20,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "76[0x01]",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Energy Reports",
"defaultValue": 1
},
{
"#": "76[0x04]",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Power Reports",
"defaultValue": 1
},
{
"#": "76[0x10]",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Voltage Reports",
"defaultValue": 1
},
{
"#": "76[0x20]",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Current Reports",
"defaultValue": 1
},
{
"#": "76[0x40]",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Power Factor Reports",
"defaultValue": 1
}
],
"metadata": {
"manual": "https://support.widom.it/wp-content/uploads/2022/11/energy-driven-switch-c-serie-700-manual-en.pdf"
}
}