{ "manufacturer": "wiDom", "manufacturerId": "0x0149", "label": "C7", "description": "Energy Driven Switch", "devices": [ { "productType": "0x0004", "productId": "0x0009" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "21", "label": "Output Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Direct load control or normally open relay", "value": 0 }, { "label": "Normally closed relay", "value": 1 } ] }, { "#": "23", "$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev", "defaultValue": 0 }, { "#": "31", "label": "Auto-Off Timer", "valueSize": 4, "unit": "0.1 seconds", "minValue": 0, "maxValue": 360000, "defaultValue": 0, "options": [ { "label": "Disabled", "value": 0 } ] }, { "#": "32", "label": "Auto-On Timer", "valueSize": 4, "unit": "0.1 seconds", "minValue": 0, "maxValue": 360000, "defaultValue": 0, "options": [ { "label": "Disabled", "value": 0 } ] }, { "#": "40", "label": "Up Power: Integrated Relay Reaction", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Turn off", "value": 0 }, { "label": "Turn on", "value": 1 } ] }, { "#": "41", "label": "Down Power: Integrated Relay Reaction", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Turn off", "value": 0 }, { "label": "Turn on", "value": 1 } ] }, { "#": "42", "label": "Meter Type", "description": "Defines how consumed (positive) and produced (negative) energy is treated", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Measure consumed and produced energy", "value": 0 }, { "label": "Measure consumed energy only, ignore produced energy", "value": 1 }, { "label": "Measure produced energy only, ignore consumed energy", "value": 2 }, { "label": "Energy is only consumed", "value": 3 }, { "label": "Energy is only produced", "value": 4 } ] }, { "#": "43", "label": "Current Transformer Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Standard type", "value": 1 }, { "label": "Type 2 version", "value": 2 } ] }, { "#": "44", "label": "Up Power: Value Sent to Association Groups", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 0, "options": [ { "label": "Off", "value": 0 }, { "label": "On (0xff)", "value": 100 } ] }, { "#": "45", "label": "Up Power: Value Sent to Association Groups", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 100, "options": [ { "label": "Off", "value": 0 }, { "label": "On (0xff)", "value": 100 } ] }, { "#": "46", "label": "Over Voltage Threshold", "valueSize": 2, "unit": "0.1 V", "minValue": 900, "maxValue": 2530, "defaultValue": 2530 }, { "#": "47", "label": "Down Voltage Threshold", "valueSize": 2, "unit": "0.1 V", "minValue": 900, "maxValue": 2530, "defaultValue": 2070 }, { "#": "50", "label": "Up Power: Threshold", "valueSize": 4, "unit": "W", "minValue": 0, "maxValue": 100000, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "51", "label": "Up Power: Energy Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Consumed", "value": 0 }, { "label": "Produced", "value": 1 } ] }, { "#": "52", "label": "Up Power: First Timeout", "description": "After this time above the Up Power threshold, an Up Power event occurs", "valueSize": 2, "unit": "seconds", "minValue": 2, "maxValue": 7200, "defaultValue": 30 }, { "#": "53", "label": "Up Power: Next Timeout", "description": "After this time above the Up Power threshold, further Up Power events occur", "valueSize": 2, "unit": "seconds", "minValue": 2, "maxValue": 7200, "defaultValue": 5 }, { "#": "54", "label": "Down Power: Threshold", "valueSize": 4, "unit": "W", "minValue": 0, "maxValue": 100000, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "55", "label": "Down Power: Energy Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Consumed", "value": 0 }, { "label": "Produced", "value": 1 } ] }, { "#": "56", "label": "Down Power: First Timeout", "description": "After this time below the Down Power threshold, an Down Power event occurs", "valueSize": 2, "unit": "seconds", "minValue": 2, "maxValue": 7200, "defaultValue": 30 }, { "#": "57", "label": "Down Power: Next Timeout", "description": "After this time below the Down Power threshold, further Down Power events occur", "valueSize": 2, "unit": "seconds", "minValue": 2, "maxValue": 7200, "defaultValue": 5 }, { "#": "58", "label": "Up/Down Power: Protection Time", "description": "How long to wait before Up/Down Power Events can be triggered again", "valueSize": 2, "unit": "seconds", "minValue": 2, "maxValue": 3600, "defaultValue": 60 }, { "#": "71", "label": "Meter Report Interval", "valueSize": 1, "unit": "minutes", "minValue": 1, "maxValue": 120, "defaultValue": 10 }, { "#": "75", "label": "Power Change Report Threshold", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 20, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "76[0x01]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Energy Reports", "defaultValue": 1 }, { "#": "76[0x04]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Power Reports", "defaultValue": 1 }, { "#": "76[0x10]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Voltage Reports", "defaultValue": 1 }, { "#": "76[0x20]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Current Reports", "defaultValue": 1 }, { "#": "76[0x40]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Power Factor Reports", "defaultValue": 1 } ], "metadata": { "manual": "https://support.widom.it/wp-content/uploads/2022/11/energy-driven-switch-c-serie-700-manual-en.pdf" } }