"manufacturer": "Jasco",
|
||
"manufacturerId": "0x0063",
|
||
"label": "28170 / ZW3105",
|
||
"description": "Plug-In 2-Outlet Dimmer, 1 Controlled, 500S",
|
||
"devices": [
|
||
{
|
||
"productType": "0x5044",
|
||
"productId": "0x3039",
|
||
"zwaveAllianceId": [1268, 2106, 2172]
|
||
}
|
||
],
|
||
"firmwareVersion": {
|
||
"min": "0.0",
|
||
"max": "255.255"
|
||
},
|
||
"associations": {
|
||
"1": {
|
||
"label": "Lifeline",
|
||
"maxNodes": 5,
|
||
"isLifeline": true
|
||
},
|
||
"2": {
|
||
"label": "Local Load",
|
||
"maxNodes": 5
|
||
},
|
||
"3": {
|
||
"label": "Double Tap",
|
||
"maxNodes": 5,
|
||
"isLifeline": true
|
||
}
|
||
},
|
||
"paramInformation": [
|
||
{
|
||
"#": "3",
|
||
"$import": "~/templates/master_template.json#led_indicator_three_options"
|
||
},
|
||
{
|
||
"#": "7",
|
||
"$import": "templates/jasco_template.json#dimmer_steps_z"
|
||
},
|
||
{
|
||
"#": "8",
|
||
"$import": "templates/jasco_template.json#dimmer_times_z"
|
||
},
|
||
{
|
||
"#": "9",
|
||
"$import": "templates/jasco_template.json#dimmer_steps"
|
||
},
|
||
{
|
||
"#": "10",
|
||
"$import": "templates/jasco_template.json#dimmer_times"
|
||
},
|
||
{
|
||
"#": "11",
|
||
"$import": "templates/jasco_template.json#dimmer_steps_a"
|
||
},
|
||
{
|
||
"#": "12",
|
||
"$import": "templates/jasco_template.json#dimmer_times_a"
|
||
}
|
||
],
|
||
"compat": {
|
||
"mapBasicSet": "event"
|
||
},
|
||
"metadata": {
|
||
"inclusion": "1. Follow the instructions for your Z-wave certified controller to include the device to the Z-wave network.\n2. Once the controller is ready to include your smart switch, single press and release the manual/program button on the smart dimmer to include it in the network.\n3. Once your controller has confirmed that the smart switch has been included, refresh the Z-wave network to optimize performance",
|
||
"exclusion": "1. Follow the instructions for your Z-wave certified controller to exclude a device from the Z-wave network.\n2. Once the controller is ready to Exclude your device, press and release the manual/program button on the smart switch to exclude it from the network",
|
||
"reset": "1. If plugged in, unplug the Switch from the receptacle.\n2. Press and hold the top button for at least 3 seconds while you plug the switch into a receptacle.\nNote: This should only be used in the event your network’s primary controller is missing or otherwise inoperable",
|
||
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2172/Binder1.pdf"
|
||
}
|
||
}
|