"manufacturer": "HANK Electronics Ltd.",
|
|
"manufacturerId": "0x0208",
|
|
"label": "HKZW-FLD01",
|
|
"description": "Flood Sensor",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0200",
|
|
"productId": "0x000f"
|
|
},
|
|
{
|
|
"productType": "0x0201",
|
|
"productId": "0x000f"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "14",
|
|
"label": "Enable/Disable Basic Set Command",
|
|
"description": "The flood sensor can send BASIC SET command to nodes associated",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "15",
|
|
"label": "Value of the Basic Set",
|
|
"description": "The flood sensor can send BASIC SET command to nodes associated",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "17",
|
|
"label": "Flooding Alarm",
|
|
"description": "Enable/Disable flooding alarm",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "18",
|
|
"label": "Shock Alarm",
|
|
"description": "Enable/Disable shock alarm",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "19",
|
|
"label": "High Temperature Alarm",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "20",
|
|
"label": "Set the High Temperature Alarm Trigger Value",
|
|
"description": "Available setting(US):-67 °C to -257 °C",
|
|
"valueSize": 2,
|
|
"minValue": -670,
|
|
"maxValue": 2570,
|
|
"defaultValue": 1040
|
|
},
|
|
{
|
|
"#": "21",
|
|
"label": "Low Temperature Alarm",
|
|
"description": "Enable/Disable low temperature alarm",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "22",
|
|
"label": "Set the Low Temperature Alarm Trigger Value",
|
|
"description": "Available setting(US):-67 °C to -257 °C",
|
|
"valueSize": 2,
|
|
"minValue": -670,
|
|
"maxValue": 2570,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "24",
|
|
"label": "Blinking LED",
|
|
"description": "Enable/Disable blinking LED when alarm being triggered",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "32",
|
|
"label": "Level of Low Battery",
|
|
"description": "This parameter defines a battery level as the \"low battery\"",
|
|
"valueSize": 1,
|
|
"minValue": 10,
|
|
"maxValue": 50,
|
|
"defaultValue": 20
|
|
}
|
|
]
|
|
}
|