{ "manufacturer": "HANK Electronics Ltd.", "manufacturerId": "0x0208", "label": "HKZW-FLD01", "description": "Flood Sensor", "devices": [ { "productType": "0x0200", "productId": "0x000f" }, { "productType": "0x0201", "productId": "0x000f" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "14", "label": "Enable/Disable Basic Set Command", "description": "The flood sensor can send BASIC SET command to nodes associated", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "15", "label": "Value of the Basic Set", "description": "The flood sensor can send BASIC SET command to nodes associated", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "17", "label": "Flooding Alarm", "description": "Enable/Disable flooding alarm", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "18", "label": "Shock Alarm", "description": "Enable/Disable shock alarm", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "19", "label": "High Temperature Alarm", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "20", "label": "Set the High Temperature Alarm Trigger Value", "description": "Available setting(US):-67 °C to -257 °C", "valueSize": 2, "minValue": -670, "maxValue": 2570, "defaultValue": 1040 }, { "#": "21", "label": "Low Temperature Alarm", "description": "Enable/Disable low temperature alarm", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "22", "label": "Set the Low Temperature Alarm Trigger Value", "description": "Available setting(US):-67 °C to -257 °C", "valueSize": 2, "minValue": -670, "maxValue": 2570, "defaultValue": 0 }, { "#": "24", "label": "Blinking LED", "description": "Enable/Disable blinking LED when alarm being triggered", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "32", "label": "Level of Low Battery", "description": "This parameter defines a battery level as the \"low battery\"", "valueSize": 1, "minValue": 10, "maxValue": 50, "defaultValue": 20 } ] }