115 lines
4.8 KiB
JSON
115 lines
4.8 KiB
JSON
{
|
|
"manufacturer": "HANK Electronics Ltd.",
|
|
"manufacturerId": "0x0208",
|
|
"label": "HKZW-SO01",
|
|
"description": "Smart Plug with Two USB Ports",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0101",
|
|
"productId": "0x0005"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "20",
|
|
"label": "Overload Protection",
|
|
"description": "If current exceeds 16.5A over 5 seconds, relay will turn off.",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 1,
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"#": "21",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off"
|
|
},
|
|
{
|
|
"#": "24",
|
|
"label": "Notification on Load Change",
|
|
"description": "Smart Plug can send notifications to association device load state changes.",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 2,
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"#": "27",
|
|
"label": "Indicator Modes",
|
|
"description": "LED in the device will indicate the state of load",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 1,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "151",
|
|
"label": "Threshold of Power Report",
|
|
"description": "Power Threshold at which to send meter report",
|
|
"valueSize": 2,
|
|
"unit": "W",
|
|
"minValue": 0,
|
|
"maxValue": 65535,
|
|
"defaultValue": 50,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "152",
|
|
"label": "Percentage Threshold of to Trigger Power Report",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 255,
|
|
"defaultValue": 10,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "171",
|
|
"label": "Power Report Frequency",
|
|
"description": "The interval of sending power report to association device (Group Lifeline).",
|
|
"valueSize": 4,
|
|
"unit": "seconds",
|
|
"minValue": 5,
|
|
"maxValue": 2678400,
|
|
"defaultValue": 30
|
|
},
|
|
{
|
|
"#": "172",
|
|
"label": "Energy Report Frequency",
|
|
"description": "The interval of sending energy report to association device (Group Lifeline).",
|
|
"valueSize": 4,
|
|
"unit": "seconds",
|
|
"minValue": 5,
|
|
"maxValue": 2678400,
|
|
"defaultValue": 300
|
|
},
|
|
{
|
|
"#": "173",
|
|
"label": "Voltage Report Frequency",
|
|
"description": "The interval of sending voltage report to association device (Group Lifeline)",
|
|
"valueSize": 4,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 2678400,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "174",
|
|
"label": "Electricity Report Frequency",
|
|
"description": "Interval for sending electricity report.",
|
|
"valueSize": 4,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 2678400,
|
|
"defaultValue": 0
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "Automatic Non-Secure Inclusion\n1. Perform the steps in the INSTALLATION section above. If the plug-in has not already been included into a Z-Wave network, the LED indicator will blink rapidly. Otherwise, the plug-in has already been included and should first be excluded by following the instructions in the EXCLUSION section below.\n2. Set your Z-Wave controller into learning mode (refer to your controller's manual for instructions). The plug-in should be recognized and automatically included into your Z-Wave network.\n3. The auto-inclusion function will be disabled after the plug-in is included.\n\nManual Non-Secure Inclusion\n1. Perform the steps in the INSTALLATION section above. If the plug-in has not already been included into a Z-Wave network, the LED indicator will blink rapidly. Otherwise, the plug-in has already been included and should first be excluded by following the instructions in the EXCLUSION section below.\n2. Set your Z-Wave® controller into learning mode (refer to your controller's manual for instructions).\n3. Triple-click the Z-Button on the plug-in. The plug-in should be recognized and included into your Z-Wave network.\n\nManual Secure Inclusion\n1. Perform the steps in the INSTALLATION section above. If the plug-in has not already been included into a Z-Wave network, the LED indicator will blink rapidly. Otherwise, the plug-in has already been included and should first be excluded by following the instructions in the EXCLUSION section below.\n2. Set your Z-Wave controller into node secure mode (refer to your controller's manual for instructions).\n3. Press and hold the Z-Button for about 3 seconds. The LED indicator will begin blinking rapidly and the plug-in should be recognized and included into your Z- Wave network.",
|
|
"exclusion": "1. Ensure that the plug-in is inserted into an AC outlet.\n2. Set your Z-Wave controller into learning mode (refer to your controller's manual for instructions).\n3. Triple-click the Z-Button. The plug-in will be removed from your Z-Wave network.",
|
|
"reset": "Note that the plug-in can only be reset if it is included in a Z-Wave network.\n1. Ensure that the plug-in is inserted into an AC outlet.\n2. Press and hold the Z-Button on the plug-in for more than 20 seconds. The LED indicator will illuminate steadily for about 3 seconds, then will begin blinking slowly."
|
|
}
|
|
}
|