{ "manufacturer": "HANK Electronics Ltd.", "manufacturerId": "0x0208", "label": "HKZW-SO01", "description": "Smart Plug with Two USB Ports", "devices": [ { "productType": "0x0101", "productId": "0x0005" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "20", "label": "Overload Protection", "description": "If current exceeds 16.5A over 5 seconds, relay will turn off.", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 1 }, { "#": "21", "$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off" }, { "#": "24", "label": "Notification on Load Change", "description": "Smart Plug can send notifications to association device load state changes.", "valueSize": 1, "minValue": 0, "maxValue": 2, "defaultValue": 1 }, { "#": "27", "label": "Indicator Modes", "description": "LED in the device will indicate the state of load", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0 }, { "#": "151", "label": "Threshold of Power Report", "description": "Power Threshold at which to send meter report", "valueSize": 2, "unit": "W", "minValue": 0, "maxValue": 65535, "defaultValue": 50, "unsigned": true }, { "#": "152", "label": "Percentage Threshold of to Trigger Power Report", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 255, "defaultValue": 10, "unsigned": true }, { "#": "171", "label": "Power Report Frequency", "description": "The interval of sending power report to association device (Group Lifeline).", "valueSize": 4, "unit": "seconds", "minValue": 5, "maxValue": 2678400, "defaultValue": 30 }, { "#": "172", "label": "Energy Report Frequency", "description": "The interval of sending energy report to association device (Group Lifeline).", "valueSize": 4, "unit": "seconds", "minValue": 5, "maxValue": 2678400, "defaultValue": 300 }, { "#": "173", "label": "Voltage Report Frequency", "description": "The interval of sending voltage report to association device (Group Lifeline)", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 0 }, { "#": "174", "label": "Electricity Report Frequency", "description": "Interval for sending electricity report.", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 0 } ], "metadata": { "inclusion": "Automatic Non-Secure Inclusion\n1. Perform the steps in the INSTALLATION section above. If the plug-in has not already been included into a Z-Wave network, the LED indicator will blink rapidly. Otherwise, the plug-in has already been included and should first be excluded by following the instructions in the EXCLUSION section below.\n2. Set your Z-Wave controller into learning mode (refer to your controller's manual for instructions). The plug-in should be recognized and automatically included into your Z-Wave network.\n3. The auto-inclusion function will be disabled after the plug-in is included.\n\nManual Non-Secure Inclusion\n1. Perform the steps in the INSTALLATION section above. If the plug-in has not already been included into a Z-Wave network, the LED indicator will blink rapidly. Otherwise, the plug-in has already been included and should first be excluded by following the instructions in the EXCLUSION section below.\n2. Set your Z-Wave® controller into learning mode (refer to your controller's manual for instructions).\n3. Triple-click the Z-Button on the plug-in. The plug-in should be recognized and included into your Z-Wave network.\n\nManual Secure Inclusion\n1. Perform the steps in the INSTALLATION section above. If the plug-in has not already been included into a Z-Wave network, the LED indicator will blink rapidly. Otherwise, the plug-in has already been included and should first be excluded by following the instructions in the EXCLUSION section below.\n2. Set your Z-Wave controller into node secure mode (refer to your controller's manual for instructions).\n3. Press and hold the Z-Button for about 3 seconds. The LED indicator will begin blinking rapidly and the plug-in should be recognized and included into your Z- Wave network.", "exclusion": "1. Ensure that the plug-in is inserted into an AC outlet.\n2. Set your Z-Wave controller into learning mode (refer to your controller's manual for instructions).\n3. Triple-click the Z-Button. The plug-in will be removed from your Z-Wave network.", "reset": "Note that the plug-in can only be reset if it is included in a Z-Wave network.\n1. Ensure that the plug-in is inserted into an AC outlet.\n2. Press and hold the Z-Button on the plug-in for more than 20 seconds. The LED indicator will illuminate steadily for about 3 seconds, then will begin blinking slowly." } }