zwave-js/.config-db/devices/0x019b/4512688.json
2025-01-10 22:05:04 -08:00

38 lines
1.6 KiB
JSON

{
"manufacturer": "Heatit",
"manufacturerId": "0x019b",
"label": "Z-Smoke Battery",
"description": "Wireless Smoke Detector",
"devices": [
{
"productType": "0x0003",
"productId": "0x3602",
"zwaveAllianceId": 4064
},
{
"productType": "0x0003",
"productId": "0x0018"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 1,
"isLifeline": true
},
"2": {
"label": "Smoke Sensor (Basic Set)",
"maxNodes": 5
}
},
"metadata": {
"inclusion": "1. Put the Z-Wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-Wave gateway or control panel manual).\n2. Within 1.5 seconds, press the Function button 3 times. The Smoke Detector will emit a 2-tone beep and the LED will turn on for ~2 seconds. Refer to the operation manual of the Z-Wave gateway or control panel to complete the learn-in process.",
"exclusion": "1. Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).\n2. Within 1.5 seconds, press the Function button 3 times and the Smoke Detector will be removed from the Z-Wave network.",
"reset": "(Only use factory reset when network Control Panel/Gateway is missing or inoperable).\nPress and hold the button of the smoke detector for 20 seconds. Release the button when you hear 3 beeps to perform factory reset.",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4064/Heatit%20Z-Smoke%20Battery%2020201214.pdf"
}
}