"manufacturer": "Climax Technology, Ltd.",
|
||
"manufacturerId": "0x018e",
|
||
"label": "BX-35ZW",
|
||
"description": "Bellbox",
|
||
"devices": [
|
||
{
|
||
"productType": "0x0002",
|
||
"productId": "0x0011",
|
||
"zwaveAllianceId": 2431
|
||
}
|
||
],
|
||
"firmwareVersion": {
|
||
"min": "0.0",
|
||
"max": "255.255"
|
||
},
|
||
"paramInformation": [
|
||
{
|
||
"#": "1",
|
||
"label": "Alarm Length",
|
||
"description": "1 minute to 10 minutes",
|
||
"valueSize": 1,
|
||
"unit": "minutes",
|
||
"minValue": 1,
|
||
"maxValue": 10,
|
||
"defaultValue": 10
|
||
},
|
||
{
|
||
"#": "2",
|
||
"label": "Alarm LED Flash",
|
||
"description": "0:disable, 1: enable",
|
||
"valueSize": 1,
|
||
"minValue": 0,
|
||
"maxValue": 1,
|
||
"defaultValue": 1
|
||
},
|
||
{
|
||
"#": "3",
|
||
"label": "Comfort LED",
|
||
"valueSize": 1,
|
||
"unit": "10 seconds",
|
||
"minValue": 0,
|
||
"maxValue": 250,
|
||
"defaultValue": 0,
|
||
"unsigned": true
|
||
},
|
||
{
|
||
"#": "4",
|
||
"label": "Tamper",
|
||
"description": "0:disable, 1: enable",
|
||
"valueSize": 1,
|
||
"minValue": 0,
|
||
"maxValue": 1,
|
||
"defaultValue": 1
|
||
}
|
||
],
|
||
"metadata": {
|
||
"inclusion": "This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.\n -Insert the two 1.5V D-Cell alkaline batteries into the battery \n compartment connecting the correct polarity as shown on the \n battery compartment lid.The Bellbox will emit a 2-tone beep.\n -Put the Z-Wave gateway or control panel into Inclusion mode (please \n refer to the Z-Wave gateway or control panel manual).\n -Within 1.5 seconds, press the Function Button 3 times.\n -Refer to the operation manual of the Z-Wave Gateway or Control \n Panel to complete the adding process.\n -If the sensor has already been added (included) into another Z-Wave \n Gateway/Control Panel, or if the sensor is unable to be added into the \n current Z-Wave Gateway/Control Panel, please exclude it first (see \n Removing Device) before attempting to include it into the current Z-\n Wave Gateway/Control Panel.",
|
||
"exclusion": "The Bellbox must be removed from existing Z-Wave network before being included into another. There are two methods available to exclude a device.\n -Put the Z-Wave gateway or control panel into Exclusion mode (please \n refer to the Z-Wave gateway or control panel manual).\n -Within 1.5 seconds, press the Function Button 3 times and the Bellbox \n will be removed from the Z-Wave network.",
|
||
"reset": "(Only use factory reset when network Control Panel/Gateway is missing or inoperable).\n -Press and hold the Function button of the Bellbox for 10 seconds to \n factory reset with all LED flashes once.\n<NOTE>\n -Factory resetting the Bellbox will restore it to factory default \n settings (excluded from the Z-Wave network). The Z-Wave gateway or \n control panel will still keep its Z-Wave settings. Please refer to the \n gateway or control panel manual on how to remove the Bellbox’s Z-\n Wave settings.",
|
||
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2431/BX-35-ZW_20170508.pdf"
|
||
}
|
||
}
|