{ "manufacturer": "Climax Technology, Ltd.", "manufacturerId": "0x018e", "label": "BX-35ZW", "description": "Bellbox", "devices": [ { "productType": "0x0002", "productId": "0x0011", "zwaveAllianceId": 2431 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Alarm Length", "description": "1 minute to 10 minutes", "valueSize": 1, "unit": "minutes", "minValue": 1, "maxValue": 10, "defaultValue": 10 }, { "#": "2", "label": "Alarm LED Flash", "description": "0:disable, 1: enable", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 1 }, { "#": "3", "label": "Comfort LED", "valueSize": 1, "unit": "10 seconds", "minValue": 0, "maxValue": 250, "defaultValue": 0, "unsigned": true }, { "#": "4", "label": "Tamper", "description": "0:disable, 1: enable", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 1 } ], "metadata": { "inclusion": "This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.\n -Insert the two 1.5V D-Cell alkaline batteries into the battery \n compartment connecting the correct polarity as shown on the \n battery compartment lid.The Bellbox will emit a 2-tone beep.\n -Put the Z-Wave gateway or control panel into Inclusion mode (please \n refer to the Z-Wave gateway or control panel manual).\n -Within 1.5 seconds, press the Function Button 3 times.\n -Refer to the operation manual of the Z-Wave Gateway or Control \n Panel to complete the adding process.\n -If the sensor has already been added (included) into another Z-Wave \n Gateway/Control Panel, or if the sensor is unable to be added into the \n current Z-Wave Gateway/Control Panel, please exclude it first (see \n Removing Device) before attempting to include it into the current Z-\n Wave Gateway/Control Panel.", "exclusion": "The Bellbox must be removed from existing Z-Wave network before being included into another. There are two methods available to exclude a device.\n -Put the Z-Wave gateway or control panel into Exclusion mode (please \n refer to the Z-Wave gateway or control panel manual).\n -Within 1.5 seconds, press the Function Button 3 times and the Bellbox \n will be removed from the Z-Wave network.", "reset": "(Only use factory reset when network Control Panel/Gateway is missing or inoperable).\n -Press and hold the Function button of the Bellbox for 10 seconds to \n factory reset with all LED flashes once.\n\n -Factory resetting the Bellbox will restore it to factory default \n settings (excluded from the Z-Wave network). The Z-Wave gateway or \n control panel will still keep its Z-Wave settings. Please refer to the \n gateway or control panel manual on how to remove the Bellbox’s Z-\n Wave settings.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2431/BX-35-ZW_20170508.pdf" } }