59 lines
1.7 KiB
JSON
59 lines
1.7 KiB
JSON
{
|
|
"manufacturer": "Popp & Co",
|
|
"manufacturerId": "0x0154",
|
|
"label": "POPE700342",
|
|
"description": "10-Years Smoke Detector without Siren",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0004",
|
|
"productId": "0x000d"
|
|
},
|
|
{
|
|
"productType": "0x0004",
|
|
"productId": "0x0010"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"associations": {
|
|
"1": {
|
|
"label": "Lifeline",
|
|
"maxNodes": 10,
|
|
"isLifeline": true
|
|
},
|
|
"2": {
|
|
"label": "Switching Command",
|
|
"maxNodes": 10,
|
|
"description": "All devices in this group will receive a BASIC SET command on Smoke Alarms. Configuration parameter 3 and 4 will define the BASIC command sent."
|
|
}
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "3",
|
|
"label": "Value of On-Command",
|
|
"description": "This value is sent as BASIC Set to Association Group 2 when an Smoke Alarm occurs.",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 99,
|
|
"defaultValue": 99
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Value of Off-Command",
|
|
"description": "This value is sent as BASIC Set to Association Group 2 when an Smoke Alarm is cleared.",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 99,
|
|
"defaultValue": 0
|
|
}
|
|
],
|
|
"metadata": {
|
|
"wakeup": "A double click on the Z-Wave button wakes up the device.",
|
|
"inclusion": "Secure Inclusion: Push the button for 3 seconds, Unsecure Inclusion: Push the button for 1 seconds",
|
|
"exclusion": "Push the button for 1 second",
|
|
"reset": "To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults.",
|
|
"manual": "https://manuals.zwave.eu/backend/make.php?lang=en&sku=pope700342&type=popp"
|
|
}
|
|
}
|