{ "manufacturer": "Popp & Co", "manufacturerId": "0x0154", "label": "POPE700342", "description": "10-Years Smoke Detector without Siren", "devices": [ { "productType": "0x0004", "productId": "0x000d" }, { "productType": "0x0004", "productId": "0x0010" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 10, "isLifeline": true }, "2": { "label": "Switching Command", "maxNodes": 10, "description": "All devices in this group will receive a BASIC SET command on Smoke Alarms. Configuration parameter 3 and 4 will define the BASIC command sent." } }, "paramInformation": [ { "#": "3", "label": "Value of On-Command", "description": "This value is sent as BASIC Set to Association Group 2 when an Smoke Alarm occurs.", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 99 }, { "#": "4", "label": "Value of Off-Command", "description": "This value is sent as BASIC Set to Association Group 2 when an Smoke Alarm is cleared.", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 0 } ], "metadata": { "wakeup": "A double click on the Z-Wave button wakes up the device.", "inclusion": "Secure Inclusion: Push the button for 3 seconds, Unsecure Inclusion: Push the button for 1 seconds", "exclusion": "Push the button for 1 second", "reset": "To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults.", "manual": "https://manuals.zwave.eu/backend/make.php?lang=en&sku=pope700342&type=popp" } }