"manufacturer": "Philio Technology Corp",
|
|
"manufacturerId": "0x013c",
|
|
"label": "PAN04",
|
|
"description": "In Wall Dual Relay Switch Module 2x1.5kW with Power Meter",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0001",
|
|
"productId": "0x0003"
|
|
},
|
|
{
|
|
"productType": "0x0001",
|
|
"productId": "0x0012"
|
|
},
|
|
{
|
|
"productType": "0x0001",
|
|
"productId": "0x0014"
|
|
},
|
|
{
|
|
"productType": "0x0001",
|
|
"productId": "0x0061"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Meter Report Period (W)",
|
|
"valueSize": 2,
|
|
"unit": "5 seconds",
|
|
"minValue": 0,
|
|
"maxValue": 65535,
|
|
"defaultValue": 720,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "kWh Meter Report Period (kWh)",
|
|
"valueSize": 2,
|
|
"unit": "10 minutes",
|
|
"minValue": 0,
|
|
"maxValue": 65535,
|
|
"defaultValue": 6,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Selected Relay",
|
|
"description": "Which relay is addressed by the BASIC command class",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Relay 1",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Relay 2",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Relay 1 + 2",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "External Switch Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Edge mode",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Pulse mode",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Edge-Toggle mode",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "Threshold for Load Caution (A)",
|
|
"description": "When this threshold is surpassed, a Meter Report will be sent.",
|
|
"valueSize": 2,
|
|
"unit": "0.01 A",
|
|
"minValue": 0,
|
|
"maxValue": 65535,
|
|
"defaultValue": 750,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Threshold for Load Caution (kWh)",
|
|
"description": "When this threshold is surpassed, a Meter Report will be sent.",
|
|
"valueSize": 2,
|
|
"unit": "kWh",
|
|
"minValue": 0,
|
|
"maxValue": 65535,
|
|
"defaultValue": 10000,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "7",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on"
|
|
},
|
|
{
|
|
"#": "8",
|
|
"label": "Auto Off Timer",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "9",
|
|
"label": "RF Off Command Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Switch off",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Ignore",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Switch toggle",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Switch on",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "10",
|
|
"label": "Endpoint 3",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Exists",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Doesn't exist",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "14",
|
|
"label": "Differential Report Threshold (W)",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "5 %",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "10 %",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "15 %",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "20 %",
|
|
"value": 4
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "31",
|
|
"label": "Send Reports From Endpoints",
|
|
"description": "Enable this to distinguish between the relays.",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 2
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode",
|
|
"exclusion": "1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.",
|
|
"reset": "1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.\n2. Within 1 second, press On/Off button again for 5 seconds.\nUse this procedure only in the event that the primary controller is lost or otherwise inoperable.",
|
|
"manual": "https://www.zwavetaiwan.com.tw/s/PAN04-manual-20181015-1.pdf"
|
|
}
|
|
}
|