{ "manufacturer": "Philio Technology Corp", "manufacturerId": "0x013c", "label": "PAN04", "description": "In Wall Dual Relay Switch Module 2x1.5kW with Power Meter", "devices": [ { "productType": "0x0001", "productId": "0x0003" }, { "productType": "0x0001", "productId": "0x0012" }, { "productType": "0x0001", "productId": "0x0014" }, { "productType": "0x0001", "productId": "0x0061" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Meter Report Period (W)", "valueSize": 2, "unit": "5 seconds", "minValue": 0, "maxValue": 65535, "defaultValue": 720, "unsigned": true }, { "#": "2", "label": "kWh Meter Report Period (kWh)", "valueSize": 2, "unit": "10 minutes", "minValue": 0, "maxValue": 65535, "defaultValue": 6, "unsigned": true }, { "#": "3", "label": "Selected Relay", "description": "Which relay is addressed by the BASIC command class", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Relay 1", "value": 1 }, { "label": "Relay 2", "value": 2 }, { "label": "Relay 1 + 2", "value": 3 } ] }, { "#": "4", "label": "External Switch Mode", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Edge mode", "value": 1 }, { "label": "Pulse mode", "value": 2 }, { "label": "Edge-Toggle mode", "value": 3 } ] }, { "#": "5", "label": "Threshold for Load Caution (A)", "description": "When this threshold is surpassed, a Meter Report will be sent.", "valueSize": 2, "unit": "0.01 A", "minValue": 0, "maxValue": 65535, "defaultValue": 750, "unsigned": true }, { "#": "6", "label": "Threshold for Load Caution (kWh)", "description": "When this threshold is surpassed, a Meter Report will be sent.", "valueSize": 2, "unit": "kWh", "minValue": 0, "maxValue": 65535, "defaultValue": 10000, "unsigned": true }, { "#": "7", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on" }, { "#": "8", "label": "Auto Off Timer", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "9", "label": "RF Off Command Mode", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Switch off", "value": 0 }, { "label": "Ignore", "value": 1 }, { "label": "Switch toggle", "value": 2 }, { "label": "Switch on", "value": 3 } ] }, { "#": "10", "label": "Endpoint 3", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Exists", "value": 1 }, { "label": "Doesn't exist", "value": 2 } ] }, { "#": "14", "label": "Differential Report Threshold (W)", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "5 %", "value": 1 }, { "label": "10 %", "value": 2 }, { "label": "15 %", "value": 3 }, { "label": "20 %", "value": 4 } ] }, { "#": "31", "label": "Send Reports From Endpoints", "description": "Enable this to distinguish between the relays.", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 1 }, { "label": "Enable", "value": 2 } ] } ], "metadata": { "inclusion": "1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode", "exclusion": "1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.\n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.", "reset": "1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.\n2. Within 1 second, press On/Off button again for 5 seconds.\nUse this procedure only in the event that the primary controller is lost or otherwise inoperable.", "manual": "https://www.zwavetaiwan.com.tw/s/PAN04-manual-20181015-1.pdf" } }