zwave-js/.config-db/devices/0x0085/zws12n.json
2025-01-10 22:05:04 -08:00

66 lines
2.6 KiB
JSON
Raw Permalink Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

{
"manufacturer": "Fakro",
"manufacturerId": "0x0085",
"label": "ZWS12",
"description": "Chain Actuator - Window Opener",
"devices": [
{
"productType": "0x0002",
"productId": "0x0011",
"zwaveAllianceId": 2477
},
{
"productType": "0x0002",
"productId": "0x0111"
},
{
"productType": "0x0002",
"productId": "0x0116"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "7",
"label": "Motor Speed I",
"valueSize": 1,
"minValue": 1,
"maxValue": 4,
"defaultValue": 2
},
{
"#": "8",
"label": "Motor Speed II (Rain Sensor)",
"valueSize": 1,
"minValue": 1,
"maxValue": 4,
"defaultValue": 2
},
{
"#": "12",
"$import": "templates/fakro_template.json#calibration"
},
{
"#": "13",
"$import": "templates/fakro_template.json#shutter_response_to_basic_set_0xff"
},
{
"#": "15",
"label": "Close After Time",
"valueSize": 1,
"unit": "minutes",
"minValue": 0,
"maxValue": 120,
"defaultValue": 0
}
],
"metadata": {
"inclusion": "Autoinclusion - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power actuator (OFF-ON-OFFON-OFF-ON) causes the introduction of actuator to Autoinclusion mode.\nPlease note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an actuator to any Z-Wave controller running in the Include procedure.\n\nInclude - This function allow you to add actuator to the network Z-Wave.\nFollow the procedure adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the actuator for 1 second",
"exclusion": "Exclude - This function allow you to remove actuator from the network Z-Wave. Follow the procedure removing device from the network Z-Wave\naccording to user manual supplied with the product. Then, press the\nprogramming button P on the actuator for 1 second. Function removes\ninformation only about network Z-Wave",
"reset": "Device Reset Locally This function allows you to reset the Z-Wave\nnetwork without the use of Z-Wave controller. Press 5 times the\nprogramming button P fast, the actuator was removed from the Z-Wave\nnetwork, restore the default parameters, name and locations. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2477/170511%20ZWS12%20User%20Manual.pdf"
}
}