2025-01-10 22:05:04 -08:00
{
"manufacturer": "Fakro",
"manufacturerId": "0x0085",
"label": "ZWS12",
"description": "Chain Actuator - Window Opener",
"devices": [
{
"productType": "0x0002",
"productId": "0x0011",
"zwaveAllianceId": 2477
},
{
"productType": "0x0002",
"productId": "0x0111"
},
{
"productType": "0x0002",
"productId": "0x0116"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "7",
"label": "Motor Speed I",
"valueSize": 1,
"minValue": 1,
"maxValue": 4,
"defaultValue": 2
},
{
"#": "8",
"label": "Motor Speed II (Rain Sensor)",
"valueSize": 1,
"minValue": 1,
"maxValue": 4,
"defaultValue": 2
},
{
"#": "12",
"$import": "templates/fakro_template.json#calibration"
},
{
"#": "13",
"$import": "templates/fakro_template.json#shutter_response_to_basic_set_0xff"
},
{
"#": "15",
"label": "Close After Time",
"valueSize": 1,
"unit": "minutes",
"minValue": 0,
"maxValue": 120,
"defaultValue": 0
}
],
"metadata": {
"inclusion": "Autoinclusion - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power actuator (OFF-ON-OFFON-OFF-ON) causes the introduction of actuator to Autoinclusion mode.\nPlease note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an actuator to any Z-Wave controller running in the Include procedure.\n\nInclude - This function allow you to add actuator to the network Z-Wave.\nFollow the procedure adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the actuator for 1 second",
"exclusion": "Exclude - This function allow you to remove actuator from the network Z-Wave. Follow the procedure removing device from the network Z-Wave\naccording to user manual supplied with the product. Then, press the\nprogramming button P on the actuator for 1 second. Function removes\ninformation only about network Z-Wave",
"reset": "Device Reset Locally This function allows you to reset the Z-Wave\nnetwork without the use of Z-Wave controller. Press 5 times the\nprogramming button P fast, the actuator was removed from the Z-Wave\nnetwork, restore the default parameters, name and locations. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2477/170511%20ZWS12%20User%20Manual.pdf"
}
}