"manufacturer": "Everspring",
|
|
"manufacturerId": "0x0060",
|
|
"label": "AN-196",
|
|
"description": "Dual Relay In-Wall Module",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0004",
|
|
"productId": "0x000e",
|
|
"zwaveAllianceId": [3633, 4640]
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"associations": {
|
|
"1": {
|
|
"label": "Lifeline",
|
|
"maxNodes": 5,
|
|
"isLifeline": true
|
|
},
|
|
"2": {
|
|
"label": "On/Off Control",
|
|
"maxNodes": 5
|
|
},
|
|
"3": {
|
|
"label": "On/Off Control",
|
|
"maxNodes": 5
|
|
}
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Switch 1 Type",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Momentary",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Toggle",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Switch 2 Type",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Momentary",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Toggle",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Auto Off Time: Relay 1",
|
|
"valueSize": 1,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 127,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Auto Off Time: Relay 2",
|
|
"valueSize": 1,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 127,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "5",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev",
|
|
"label": "State After Power Failure: Relay 1"
|
|
},
|
|
{
|
|
"#": "6",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev",
|
|
"label": "State After Power Failure: Relay 2"
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "1.Put the Z-Wave Controller into inclusion mode.\n2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode.",
|
|
"exclusion": "1. Put the Z-Wave Controller into exclusion mode.\n2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.",
|
|
"reset": "1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.\n2. Within 1 second of step 1, press link key again and hold until LED is off (about 5 seconds).\n3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes.",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4640/AN-196%20user%20manual.pdf"
|
|
}
|
|
}
|