"manufacturer": "Everspring",
|
|
"manufacturerId": "0x0060",
|
|
"label": "AN181",
|
|
"description": "Mini Plug Switch with Metering (Gen5)",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0004",
|
|
"productId": "0x0006"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Command Value",
|
|
"description": "Set Basic Set Command value to be sent to group 2 when switch is turned on",
|
|
"valueSize": 2,
|
|
"minValue": 0,
|
|
"maxValue": 255,
|
|
"defaultValue": 255,
|
|
"options": [
|
|
{
|
|
"label": "No Basic Set command will be sent",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Basic Set command on will be sent",
|
|
"value": 255
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Delaying Time",
|
|
"description": "Set the delaying time to report to Group 1 in seconds",
|
|
"valueSize": 1,
|
|
"unit": "seconds",
|
|
"minValue": 3,
|
|
"maxValue": 25,
|
|
"defaultValue": 3
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Remember Status",
|
|
"description": "Set whether to remember the last status",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Do not remember",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Remember",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Interval for Wattage Auto Report",
|
|
"valueSize": 2,
|
|
"unit": "minutes",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 1,
|
|
"options": [
|
|
{
|
|
"label": "Does not report automatically",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "Interval for kW*h Auto Report",
|
|
"valueSize": 2,
|
|
"unit": "minutes",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 60,
|
|
"options": [
|
|
{
|
|
"label": "Does not report automatically",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Auto Report Load Surpasses Value",
|
|
"valueSize": 2,
|
|
"unit": "W",
|
|
"minValue": 0,
|
|
"maxValue": 2500,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Does not report automatically",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "7",
|
|
"label": "Auto Report Change Percentage",
|
|
"description": "Auto report when the change of wattage surpasses the set percentage",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Does not report automatically",
|
|
"value": 0
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|