{ "manufacturer": "Everspring", "manufacturerId": "0x0060", "label": "AN181", "description": "Mini Plug Switch with Metering (Gen5)", "devices": [ { "productType": "0x0004", "productId": "0x0006" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Command Value", "description": "Set Basic Set Command value to be sent to group 2 when switch is turned on", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255, "options": [ { "label": "No Basic Set command will be sent", "value": 0 }, { "label": "Basic Set command on will be sent", "value": 255 } ] }, { "#": "2", "label": "Delaying Time", "description": "Set the delaying time to report to Group 1 in seconds", "valueSize": 1, "unit": "seconds", "minValue": 3, "maxValue": 25, "defaultValue": 3 }, { "#": "3", "label": "Remember Status", "description": "Set whether to remember the last status", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Do not remember", "value": 0 }, { "label": "Remember", "value": 1 } ] }, { "#": "4", "label": "Interval for Wattage Auto Report", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 32767, "defaultValue": 1, "options": [ { "label": "Does not report automatically", "value": 0 } ] }, { "#": "5", "label": "Interval for kW*h Auto Report", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 32767, "defaultValue": 60, "options": [ { "label": "Does not report automatically", "value": 0 } ] }, { "#": "6", "label": "Auto Report Load Surpasses Value", "valueSize": 2, "unit": "W", "minValue": 0, "maxValue": 2500, "defaultValue": 0, "options": [ { "label": "Does not report automatically", "value": 0 } ] }, { "#": "7", "label": "Auto Report Change Percentage", "description": "Auto report when the change of wattage surpasses the set percentage", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 0, "options": [ { "label": "Does not report automatically", "value": 0 } ] } ] }