"manufacturer": "Flex Automation",
"manufacturerId": "0x002c",
"label": "Z-FLEXNET DONGL",
"description": "FlexNET Dongle",
"devices": [
{
"productType": "0x0002",
"productId": "0x0007",
"zwaveAllianceId": 2804
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Set Buzzer",
"description": "00 - turn off buzzer / 01 - turn on buzzer",
"valueSize": 1,
"minValue": 0,
"maxValue": 1,
"defaultValue": 1
},
{
"#": "2",
"label": "Set Clock",
"description": "First byte = Hour, Second byte = Minute",
"valueSize": 2,
"minValue": 0,
"maxValue": 6203,
"defaultValue": 0
},
{
"#": "3",
"label": "Eco Mode Channel 01",
"description": "30 - minimum limit / 100 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 100
},
{
"#": "4",
"label": "Eco Mode Channel 02",
"description": "30 - minimum limit / 100 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 100
},
{
"#": "5",
"label": "Eco Mode Channel 03",
"description": "30 - minimum limit / 100 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 100
},
{
"#": "6",
"label": "Eco Mode Channel 04",
"description": "30 - minimum limit / 100 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 100
},
{
"#": "7",
"label": "Eco Mode Channel 05",
"description": "30 - minimum limit / 100 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 100
},
{
"#": "8",
"label": "Eco Mode Channel 06",
"description": "30 - minimum limit / 100 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 100
},
{
"#": "9",
"label": "Dimmer Minimum Level Channel 01",
"description": "29 - minimum limit / 99 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 29
},
{
"#": "10",
"label": "Dimmer Minimum Level Channel 02",
"description": "29 - minimum limit / 99 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 29,
"defaultValue": 29
},
{
"#": "11",
"label": "Dimmer Minimum Level Channel 03",
"description": "29 - minimum limit / 99 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 29
},
{
"#": "12",
"label": "Dimmer Minimum Level Channel 04",
"description": "29 - minimum limit / 99 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 29
},
{
"#": "13",
"label": "Dimmer Minimum Level Channel 05",
"description": "29 - minimum limit / 99 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 29
},
{
"#": "14",
"label": "Dimmer Minimum Level Channel 06",
"description": "29 - minimum limit / 99 - maximum limit",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 29
},
{
"#": "15",
"label": "Reset to Factory Default",
"valueSize": 1,
"defaultValue": 0,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Idle",
"value": 0
},
{
"label": "Factory reset",
"value": 255
}
]
}
],
"metadata": {
"inclusion": "1. Enter your Z-Wave Controller into Inclusion/Add Mode.\n2. Press the Lighting Panel \"Scene1\" button more than 3 times within 1 second.\nOR, to use NWI:\n1. Enter your Z-Wave Controller into Inclusion/Add Mode.\n2. Power on the FlexNET Dongle. It will be active during 4 seconds",
"exclusion": "1. Enter your Z-Wave Controller into Exclusion/Remove Mode.\n2. Press the Lighting Panel \"Scene1\" button more than 3 times within 1 second",
"reset": "To Reset to Factory Default send the following parameter:\nParameter: 15\nBytes: 01\nValue: 255\n\nNote: Please use this procedure only when the network primary controller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2804/FlexNET%20Dongle_Device%20Manual_v5.pdf"
}
}