{ "manufacturer": "Flex Automation", "manufacturerId": "0x002c", "label": "Z-FLEXNET DONGL", "description": "FlexNET Dongle", "devices": [ { "productType": "0x0002", "productId": "0x0007", "zwaveAllianceId": 2804 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Set Buzzer", "description": "00 - turn off buzzer / 01 - turn on buzzer", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 1 }, { "#": "2", "label": "Set Clock", "description": "First byte = Hour, Second byte = Minute", "valueSize": 2, "minValue": 0, "maxValue": 6203, "defaultValue": 0 }, { "#": "3", "label": "Eco Mode Channel 01", "description": "30 - minimum limit / 100 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 100 }, { "#": "4", "label": "Eco Mode Channel 02", "description": "30 - minimum limit / 100 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 100 }, { "#": "5", "label": "Eco Mode Channel 03", "description": "30 - minimum limit / 100 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 100 }, { "#": "6", "label": "Eco Mode Channel 04", "description": "30 - minimum limit / 100 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 100 }, { "#": "7", "label": "Eco Mode Channel 05", "description": "30 - minimum limit / 100 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 100 }, { "#": "8", "label": "Eco Mode Channel 06", "description": "30 - minimum limit / 100 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 100 }, { "#": "9", "label": "Dimmer Minimum Level Channel 01", "description": "29 - minimum limit / 99 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 29 }, { "#": "10", "label": "Dimmer Minimum Level Channel 02", "description": "29 - minimum limit / 99 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 29, "defaultValue": 29 }, { "#": "11", "label": "Dimmer Minimum Level Channel 03", "description": "29 - minimum limit / 99 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 29 }, { "#": "12", "label": "Dimmer Minimum Level Channel 04", "description": "29 - minimum limit / 99 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 29 }, { "#": "13", "label": "Dimmer Minimum Level Channel 05", "description": "29 - minimum limit / 99 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 29 }, { "#": "14", "label": "Dimmer Minimum Level Channel 06", "description": "29 - minimum limit / 99 - maximum limit", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 29 }, { "#": "15", "label": "Reset to Factory Default", "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Idle", "value": 0 }, { "label": "Factory reset", "value": 255 } ] } ], "metadata": { "inclusion": "1. Enter your Z-Wave Controller into Inclusion/Add Mode.\n2. Press the Lighting Panel \"Scene1\" button more than 3 times within 1 second.\nOR, to use NWI:\n1. Enter your Z-Wave Controller into Inclusion/Add Mode.\n2. Power on the FlexNET Dongle. It will be active during 4 seconds", "exclusion": "1. Enter your Z-Wave Controller into Exclusion/Remove Mode.\n2. Press the Lighting Panel \"Scene1\" button more than 3 times within 1 second", "reset": "To Reset to Factory Default send the following parameter:\nParameter: 15\nBytes: 01\nValue: 255\n\nNote: Please use this procedure only when the network primary controller is missing or otherwise inoperable", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2804/FlexNET%20Dongle_Device%20Manual_v5.pdf" } }