"manufacturer": "HomeSeer Technologies",
|
|
"manufacturerId": "0x000c",
|
|
"label": "HS-FLS100+",
|
|
"description": "Floodlight Sensor",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0201",
|
|
"productId": "0x000b",
|
|
"zwaveAllianceId": 2947
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"$import": "templates/homeseer_template.json#pir_trigger_off"
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Light Level Threshold",
|
|
"description": "Activate floodlight and send Basic Set Command when PIR is triggered while light level is below this threshold.",
|
|
"valueSize": 2,
|
|
"unit": "lux",
|
|
"minValue": 0,
|
|
"maxValue": 255,
|
|
"defaultValue": 50,
|
|
"options": [
|
|
{
|
|
"label": "Never turn on floodlight",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Ignore light level",
|
|
"value": 255
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"$import": "templates/homeseer_template.json#multilevel_sensor_interval",
|
|
"label": "Luminance Report Interval"
|
|
},
|
|
{
|
|
"#": "4",
|
|
"$import": "~/templates/master_template.json#base_enable_disable",
|
|
"label": "Send Basic Report On Trigger"
|
|
}
|
|
],
|
|
"compat": {
|
|
"commandClasses": {
|
|
"remove": {
|
|
"Supervision": {
|
|
// The device reports that it supports Supervision, but it does not support all
|
|
// commands supervision-encapsulated
|
|
"endpoints": "*"
|
|
}
|
|
}
|
|
}
|
|
},
|
|
"metadata": {
|
|
"inclusion": "Z-Wave auto inclusion.\nOr manual inclusion : put the Z-Wave controller into inclusion mode, press the Link button 3 times within 1.5 seconds to put the unit into inclusion mode",
|
|
"exclusion": "Put the Z-Wave Controller into exclusion mode. Press the Link button 3 times within 1.5 seconds to put the unit into exclusion mode",
|
|
"reset": "The product reset is to operate only when the primary controller is missing or inoperable. Press the Link button 3 times within 1.5 seconds to put the unit into exclusion mode.Within 1 second of step 1, press the Link button again and hold until LED is off (about 5 seconds)",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2947/HS-FLS100-user-manual2b-A501112779R.pdf"
|
|
}
|
|
}
|