zwave-js/.config-db/devices/0x019a/11_01_022.json

140 lines
3.5 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Sensative AB",
"manufacturerId": "0x019a",
"label": "11-01-022",
"description": "Strips Guard 700",
"devices": [
{
"productType": "0x0004",
"productId": "0x0004",
"zwaveAllianceId": [4155, 4160, 4300, 4441, 4447]
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 1,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"label": "Notification Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Binary Sensor Report & Notification Report (Access control)",
"value": 0
},
{
"label": "Notification Report (Access control)",
"value": 1
},
{
"label": "Notification Report (Home security)",
"value": 2
}
]
},
{
"#": "2",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "LED Indicator",
"defaultValue": 1
},
{
"#": "15",
"label": "Send Supervision Commands",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Events with S2 encapsulation only",
"value": 0
},
{
"label": "Only door open alarm reports",
"value": 1
},
{
"label": "Unsolicited reports",
"value": 2
}
]
},
{
"#": "16",
"label": "Supervision Report Wait Time",
"valueSize": 2,
"unit": "ms",
"minValue": 500,
"maxValue": 30000,
"defaultValue": 10000
},
{
"#": "17",
"label": "Number of Failed Event Retries",
"valueSize": 1,
"minValue": 0,
"maxValue": 5,
"defaultValue": 1,
"options": [
{
"label": "No retries",
"value": 0
}
]
},
{
"#": "18",
"label": "Failed Event Retry Interval",
"valueSize": 1,
"unit": "seconds",
"minValue": 1,
"maxValue": 60,
"defaultValue": 6
},
{
"#": "19",
"label": "Heartbeat Interval",
"valueSize": 1,
"unit": "minutes",
"minValue": 5,
"maxValue": 70,
"defaultValue": 70
},
{
"#": "22",
"label": "Security Level",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Standard",
"value": 0
},
{
"label": "High",
"value": 1
}
]
}
],
"metadata": {
"inclusion": "Set your controller in include mode (see your controllers manual). Follow the instruction below for Wake up. A long LED blink indicates that the inclusion was successful.\n\nTo wake up Strips manually for communication with the Z-Wave controller, move the magnet towards and away from the rounded edge. Repeat 3 times.",
"exclusion": "Set your controller in exclude mode (see your controllers manual). Follow the instruction below for Wake up. A long LED blink indicates that the exclusion was successful.\n\nTo wake up Strips manually for communication with the Z-Wave controller, move the magnet towards and away from the rounded edge. Repeat 3 times.",
"reset": "You may need to reset Strips if your Z-Wave controller is missing or not responding.\n\nFollow the instructions for “Wake up” above, but on the 3rd repetition, keep the magnet at the rounded edge for 10 seconds. A long LED signal indicates success",
"wakeup": "Place a magnet at the rounded edge. When the LED blinks, move the magnet away. Repeat a total of 3 times within 10 seconds, A LED blink indicates success.",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4300/Strips%20Drip%20700%20manual.pdf"
}
}