{ "manufacturer": "Sensative AB", "manufacturerId": "0x019a", "label": "11-01-022", "description": "Strips Guard 700", "devices": [ { "productType": "0x0004", "productId": "0x0004", "zwaveAllianceId": [4155, 4160, 4300, 4441, 4447] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Notification Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Binary Sensor Report & Notification Report (Access control)", "value": 0 }, { "label": "Notification Report (Access control)", "value": 1 }, { "label": "Notification Report (Home security)", "value": 2 } ] }, { "#": "2", "$import": "~/templates/master_template.json#base_enable_disable", "label": "LED Indicator", "defaultValue": 1 }, { "#": "15", "label": "Send Supervision Commands", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Events with S2 encapsulation only", "value": 0 }, { "label": "Only door open alarm reports", "value": 1 }, { "label": "Unsolicited reports", "value": 2 } ] }, { "#": "16", "label": "Supervision Report Wait Time", "valueSize": 2, "unit": "ms", "minValue": 500, "maxValue": 30000, "defaultValue": 10000 }, { "#": "17", "label": "Number of Failed Event Retries", "valueSize": 1, "minValue": 0, "maxValue": 5, "defaultValue": 1, "options": [ { "label": "No retries", "value": 0 } ] }, { "#": "18", "label": "Failed Event Retry Interval", "valueSize": 1, "unit": "seconds", "minValue": 1, "maxValue": 60, "defaultValue": 6 }, { "#": "19", "label": "Heartbeat Interval", "valueSize": 1, "unit": "minutes", "minValue": 5, "maxValue": 70, "defaultValue": 70 }, { "#": "22", "label": "Security Level", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Standard", "value": 0 }, { "label": "High", "value": 1 } ] } ], "metadata": { "inclusion": "Set your controller in include mode (see your controller’s manual). Follow the instruction below for Wake up. A long LED blink indicates that the inclusion was successful.\n\nTo wake up Strips manually for communication with the Z-Wave controller, move the magnet towards and away from the rounded edge. Repeat 3 times.", "exclusion": "Set your controller in exclude mode (see your controller’s manual). Follow the instruction below for Wake up. A long LED blink indicates that the exclusion was successful.\n\nTo wake up Strips manually for communication with the Z-Wave controller, move the magnet towards and away from the rounded edge. Repeat 3 times.", "reset": "You may need to reset Strips if your Z-Wave controller is missing or not responding.\n\nFollow the instructions for “Wake up” above, but on the 3rd repetition, keep the magnet at the rounded edge for 10 seconds. A long LED signal indicates success", "wakeup": "Place a magnet at the rounded edge. When the LED blinks, move the magnet away. Repeat a total of 3 times within 10 seconds, A LED blink indicates success.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4300/Strips%20Drip%20700%20manual.pdf" } }