"manufacturer": "Ness Corporation Pty Ltd.",
"manufacturerId": "0x0189",
"label": "117001",
"description": "Z-Wave LUX PIR Sensor",
"devices": [
{
"productType": "0x0104",
"productId": "0x0301",
"zwaveAllianceId": 4249
},
{
"productType": "0x0204",
"productId": "0x0301",
"zwaveAllianceId": 4158
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"label": "Motion Retrigger Timeout",
"valueSize": 2,
"unit": "seconds",
"minValue": 10,
"maxValue": 3600,
"defaultValue": 240,
"options": [
{
"label": "Disable",
"value": 10
}
]
},
{
"#": "2",
"label": "Motion Retrigger Timeout Reset Mode",
"valueSize": 1,
"minValue": 0,
"maxValue": 1,
"defaultValue": 0,
"options": [
{
"label": "Restart timeout with each motion event",
"value": 0
},
{
"label": "Calculate timeout from initial motion event",
"value": 1
}
]
},
{
"#": "3",
"label": "Motion Reset Timeout",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 3600,
"defaultValue": 10,
"options": [
{
"label": "Disable motion clear report",
"value": 0
}
]
},
{
"#": "4",
"label": "Low Battery Threshold",
"valueSize": 1,
"unit": "%",
"minValue": 10,
"maxValue": 50,
"defaultValue": 10
},
{
"#": "5",
"label": "Battery Reporting Interval",
"valueSize": 1,
"unit": "minutes",
"minValue": 0,
"maxValue": 120,
"defaultValue": 12,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "6",
"label": "Luminance Change Threshold",
"valueSize": 1,
"unit": "lux",
"minValue": 0,
"maxValue": 60,
"defaultValue": 50,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "7",
"label": "Temperature Change Threshold",
"valueSize": 1,
"unit": "0.1 °C/°F",
"minValue": 0,
"maxValue": 80,
"defaultValue": 10
},
{
"#": "8",
"label": "Temperature Reporting Interval",
"valueSize": 1,
"unit": "30 minutes",
"minValue": 0,
"maxValue": 120,
"defaultValue": 6,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "9",
"$import": "~/templates/master_template.json#temperature_scale_celsius_fahrenheit"
},
{
"#": "10",
"label": "Night Light Duration",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "10 seconds",
"value": 0
},
{
"label": "30 seconds",
"value": 1
}
]
},
{
"#": "11",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Night Light with Low Ambient Light",
"description": "If enabled, the night light will function despite a low ambient light level"
},
{
"#": "12",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Tamper Alarm Reporting"
},
{
"#": "13",
"label": "Walk Test Mode Duration",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "10 minutes",
"value": 1
},
{
"label": "30 minutes",
"value": 2
},
{
"label": "60 minutes",
"value": 3
}
]
}
],
"metadata": {
"inclusion": "Power up the LUX Z-Wave sensor by inserting the batteries (or fit the batteries in the correct polarity).\nYou may need to refer to your Z-Wave controllers instructions for adding devices.\n1. Put your primary Z-Wave gateway into inclusion mode, the gateway should confirm that it is waiting to add a new device,\n2. Press the Z-Wave Action button on your LUX Z-Wave sensor for 1 second.\n3. The LED on the LUX Z-Wave sensor will blink Red rapidly, followed by a solid Green LED for 1 second for successful inclusion, or a solid red LED for 1 second for a failed inclusion",
"exclusion": "1. Put your primary Z-Wave gateway into exclude mode, the gateway should confirm that it is waiting to remove a device,\n2. Press the Z-Wave Action button on your LUX Z-Wave sensor for 1 second.\n3. The LED on the LUX Z-Wave sensor will display a solid Green LED for 1 second after successful exclusion",
"reset": "To reset all LUX Z-Wave sensor settings to factory default, press and hold the Z-Wave Action button for 20 seconds and release. This will remove any previous Z- Wave network inclusion credentials and reset any user set parameters.",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4158/890-493_LUX_ZWave_Manual_Rev1.0_Draft9.pdf"
}
}