{ "manufacturer": "Ness Corporation Pty Ltd.", "manufacturerId": "0x0189", "label": "117001", "description": "Z-Wave LUX PIR Sensor", "devices": [ { "productType": "0x0104", "productId": "0x0301", "zwaveAllianceId": 4249 }, { "productType": "0x0204", "productId": "0x0301", "zwaveAllianceId": 4158 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 5, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Motion Retrigger Timeout", "valueSize": 2, "unit": "seconds", "minValue": 10, "maxValue": 3600, "defaultValue": 240, "options": [ { "label": "Disable", "value": 10 } ] }, { "#": "2", "label": "Motion Retrigger Timeout Reset Mode", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Restart timeout with each motion event", "value": 0 }, { "label": "Calculate timeout from initial motion event", "value": 1 } ] }, { "#": "3", "label": "Motion Reset Timeout", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 3600, "defaultValue": 10, "options": [ { "label": "Disable motion clear report", "value": 0 } ] }, { "#": "4", "label": "Low Battery Threshold", "valueSize": 1, "unit": "%", "minValue": 10, "maxValue": 50, "defaultValue": 10 }, { "#": "5", "label": "Battery Reporting Interval", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 120, "defaultValue": 12, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "6", "label": "Luminance Change Threshold", "valueSize": 1, "unit": "lux", "minValue": 0, "maxValue": 60, "defaultValue": 50, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "7", "label": "Temperature Change Threshold", "valueSize": 1, "unit": "0.1 °C/°F", "minValue": 0, "maxValue": 80, "defaultValue": 10 }, { "#": "8", "label": "Temperature Reporting Interval", "valueSize": 1, "unit": "30 minutes", "minValue": 0, "maxValue": 120, "defaultValue": 6, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "9", "$import": "~/templates/master_template.json#temperature_scale_celsius_fahrenheit" }, { "#": "10", "label": "Night Light Duration", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "10 seconds", "value": 0 }, { "label": "30 seconds", "value": 1 } ] }, { "#": "11", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Night Light with Low Ambient Light", "description": "If enabled, the night light will function despite a low ambient light level" }, { "#": "12", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Tamper Alarm Reporting" }, { "#": "13", "label": "Walk Test Mode Duration", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "10 minutes", "value": 1 }, { "label": "30 minutes", "value": 2 }, { "label": "60 minutes", "value": 3 } ] } ], "metadata": { "inclusion": "Power up the LUX Z-Wave sensor by inserting the batteries (or fit the batteries in the correct polarity).\nYou may need to refer to your Z-Wave controller’s instructions for adding devices.\n1. Put your primary Z-Wave gateway into inclusion mode, the gateway should confirm that it is waiting to add a new device,\n2. Press the Z-Wave Action button on your LUX Z-Wave sensor for 1 second.\n3. The LED on the LUX Z-Wave sensor will blink Red rapidly, followed by a solid Green LED for 1 second for successful inclusion, or a solid red LED for 1 second for a failed inclusion", "exclusion": "1. Put your primary Z-Wave gateway into exclude mode, the gateway should confirm that it is waiting to remove a device,\n2. Press the Z-Wave Action button on your LUX Z-Wave sensor for 1 second.\n3. The LED on the LUX Z-Wave sensor will display a solid Green LED for 1 second after successful exclusion", "reset": "To reset all LUX Z-Wave sensor settings to factory default, press and hold the Z-Wave Action button for 20 seconds and release. This will remove any previous Z- Wave network inclusion credentials and reset any user set parameters.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4158/890-493_LUX_ZWave_Manual_Rev1.0_Draft9.pdf" } }