"manufacturer": "Heatit",
|
||
|
"manufacturerId": "0x019b",
|
||
|
"label": "Z-RELAY",
|
||
|
"description": "Multipurpose Relay",
|
||
|
"devices": [
|
||
|
{
|
||
|
"productType": "0x0003",
|
||
|
"productId": "0x0208"
|
||
|
}
|
||
|
],
|
||
|
"firmwareVersion": {
|
||
|
"min": "0.0",
|
||
|
"max": "255.255"
|
||
|
},
|
||
|
"paramInformation": [
|
||
|
{
|
||
|
"#": "1",
|
||
|
"label": "Status LED",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 1,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "LED turned off",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "LED turned on",
|
||
|
"value": 1
|
||
|
},
|
||
|
{
|
||
|
"label": "LED flashing at 1 second intervals",
|
||
|
"value": 2
|
||
|
},
|
||
|
{
|
||
|
"label": "LED flashing at ½ second interval",
|
||
|
"value": 3
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "2",
|
||
|
"label": "LED Brightness",
|
||
|
"valueSize": 1,
|
||
|
"unit": "%",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 100,
|
||
|
"defaultValue": 50
|
||
|
},
|
||
|
{
|
||
|
"#": "3",
|
||
|
"label": "Thermistor Type Input 1",
|
||
|
"description": "This parameter decides which kind of thermistor is connected to input 1.",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 0,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "No thermistor, input is disabled",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "10K NTC",
|
||
|
"value": 1
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "4",
|
||
|
"label": "Thermistor Type Input 2",
|
||
|
"description": "This parameter decides which kind of thermistor is connected to input 2.",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 0,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "No thermistor, input is disabled",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "10K NTC",
|
||
|
"value": 1
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "5",
|
||
|
"label": "Input 1 Calibration",
|
||
|
"valueSize": 1,
|
||
|
"unit": "0.1 °C",
|
||
|
"minValue": -40,
|
||
|
"maxValue": 40,
|
||
|
"defaultValue": 0
|
||
|
},
|
||
|
{
|
||
|
"#": "6",
|
||
|
"label": "Input 2 Calibration",
|
||
|
"valueSize": 1,
|
||
|
"unit": "0.1 °C",
|
||
|
"minValue": -40,
|
||
|
"maxValue": 40,
|
||
|
"defaultValue": 0
|
||
|
},
|
||
|
{
|
||
|
"#": "7",
|
||
|
"label": "Input 1 Report Interval",
|
||
|
"valueSize": 2,
|
||
|
"unit": "10 seconds",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 8640,
|
||
|
"defaultValue": 6
|
||
|
},
|
||
|
{
|
||
|
"#": "8",
|
||
|
"label": "Input 2 Report Interval",
|
||
|
"valueSize": 2,
|
||
|
"unit": "10 seconds",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 8640,
|
||
|
"defaultValue": 6
|
||
|
},
|
||
|
{
|
||
|
"#": "9",
|
||
|
"label": "Flood Sensor Report Interval",
|
||
|
"valueSize": 2,
|
||
|
"unit": "10 seconds",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 8640,
|
||
|
"defaultValue": 2
|
||
|
},
|
||
|
{
|
||
|
"#": "10",
|
||
|
"label": "Meter Reports Interval",
|
||
|
"valueSize": 2,
|
||
|
"unit": "10 seconds",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 8640,
|
||
|
"defaultValue": 90
|
||
|
},
|
||
|
{
|
||
|
"#": "11",
|
||
|
"label": "Input 3 Flood Steady Timer",
|
||
|
"description": "Defines the time after which the flood sensor state will be considered valid",
|
||
|
"valueSize": 1,
|
||
|
"unit": "seconds",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 60,
|
||
|
"defaultValue": 6
|
||
|
},
|
||
|
{
|
||
|
"#": "12",
|
||
|
"label": "Auto Relay On",
|
||
|
"description": "Configures which events will cause the relay to be turned on",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 1,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "Not automatically turned on",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "Flood detected",
|
||
|
"value": 1
|
||
|
},
|
||
|
{
|
||
|
"label": "No flood detected",
|
||
|
"value": 2
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "13",
|
||
|
"label": "Auto Relay Off",
|
||
|
"description": "Configures which events will cause the relay to be turned off",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 2,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "Not automatically turned off",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "Flood detected",
|
||
|
"value": 1
|
||
|
},
|
||
|
{
|
||
|
"label": "No flood detected",
|
||
|
"value": 2
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "14",
|
||
|
"label": "Flood Detection Threshold",
|
||
|
"description": "Configures the threshold for input 3 that will cause a flood to be detected.",
|
||
|
"valueSize": 2,
|
||
|
"minValue": 0,
|
||
|
"maxValue": 4095,
|
||
|
"defaultValue": 2048
|
||
|
},
|
||
|
{
|
||
|
"#": "15",
|
||
|
"label": "Voltage",
|
||
|
"description": "Voltage value used for power calculation.",
|
||
|
"valueSize": 1,
|
||
|
"unit": "V",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 250,
|
||
|
"defaultValue": 220,
|
||
|
"unsigned": true
|
||
|
},
|
||
|
{
|
||
|
"#": "17",
|
||
|
"label": "Digital Value Per Ampere",
|
||
|
"description": "Note: Heatit recommends not changing this value unless instructed to do so",
|
||
|
"valueSize": 1,
|
||
|
"minValue": 0,
|
||
|
"maxValue": 255,
|
||
|
"defaultValue": 81,
|
||
|
"unsigned": true
|
||
|
},
|
||
|
{
|
||
|
"#": "18",
|
||
|
"label": "Load Size Connect to Relay Output",
|
||
|
"description": "Actual load in Watt.",
|
||
|
"valueSize": 2,
|
||
|
"unit": "W",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 6000,
|
||
|
"defaultValue": 0
|
||
|
}
|
||
|
],
|
||
|
"compat": {
|
||
|
"commandClasses": {
|
||
|
"remove": {
|
||
|
// The device does not support Supervision correctly
|
||
|
"Supervision": {
|
||
|
"endpoints": "*"
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|