{ "manufacturer": "Heatit", "manufacturerId": "0x019b", "label": "Z-RELAY", "description": "Multipurpose Relay", "devices": [ { "productType": "0x0003", "productId": "0x0208" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Status LED", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "LED turned off", "value": 0 }, { "label": "LED turned on", "value": 1 }, { "label": "LED flashing at 1 second intervals", "value": 2 }, { "label": "LED flashing at ½ second interval", "value": 3 } ] }, { "#": "2", "label": "LED Brightness", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 50 }, { "#": "3", "label": "Thermistor Type Input 1", "description": "This parameter decides which kind of thermistor is connected to input 1.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "No thermistor, input is disabled", "value": 0 }, { "label": "10K NTC", "value": 1 } ] }, { "#": "4", "label": "Thermistor Type Input 2", "description": "This parameter decides which kind of thermistor is connected to input 2.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "No thermistor, input is disabled", "value": 0 }, { "label": "10K NTC", "value": 1 } ] }, { "#": "5", "label": "Input 1 Calibration", "valueSize": 1, "unit": "0.1 °C", "minValue": -40, "maxValue": 40, "defaultValue": 0 }, { "#": "6", "label": "Input 2 Calibration", "valueSize": 1, "unit": "0.1 °C", "minValue": -40, "maxValue": 40, "defaultValue": 0 }, { "#": "7", "label": "Input 1 Report Interval", "valueSize": 2, "unit": "10 seconds", "minValue": 0, "maxValue": 8640, "defaultValue": 6 }, { "#": "8", "label": "Input 2 Report Interval", "valueSize": 2, "unit": "10 seconds", "minValue": 0, "maxValue": 8640, "defaultValue": 6 }, { "#": "9", "label": "Flood Sensor Report Interval", "valueSize": 2, "unit": "10 seconds", "minValue": 0, "maxValue": 8640, "defaultValue": 2 }, { "#": "10", "label": "Meter Reports Interval", "valueSize": 2, "unit": "10 seconds", "minValue": 0, "maxValue": 8640, "defaultValue": 90 }, { "#": "11", "label": "Input 3 Flood Steady Timer", "description": "Defines the time after which the flood sensor state will be considered valid", "valueSize": 1, "unit": "seconds", "minValue": 0, "maxValue": 60, "defaultValue": 6 }, { "#": "12", "label": "Auto Relay On", "description": "Configures which events will cause the relay to be turned on", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Not automatically turned on", "value": 0 }, { "label": "Flood detected", "value": 1 }, { "label": "No flood detected", "value": 2 } ] }, { "#": "13", "label": "Auto Relay Off", "description": "Configures which events will cause the relay to be turned off", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Not automatically turned off", "value": 0 }, { "label": "Flood detected", "value": 1 }, { "label": "No flood detected", "value": 2 } ] }, { "#": "14", "label": "Flood Detection Threshold", "description": "Configures the threshold for input 3 that will cause a flood to be detected.", "valueSize": 2, "minValue": 0, "maxValue": 4095, "defaultValue": 2048 }, { "#": "15", "label": "Voltage", "description": "Voltage value used for power calculation.", "valueSize": 1, "unit": "V", "minValue": 0, "maxValue": 250, "defaultValue": 220, "unsigned": true }, { "#": "17", "label": "Digital Value Per Ampere", "description": "Note: Heatit recommends not changing this value unless instructed to do so", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 81, "unsigned": true }, { "#": "18", "label": "Load Size Connect to Relay Output", "description": "Actual load in Watt.", "valueSize": 2, "unit": "W", "minValue": 0, "maxValue": 6000, "defaultValue": 0 } ], "compat": { "commandClasses": { "remove": { // The device does not support Supervision correctly "Supervision": { "endpoints": "*" } } } } }