zwave-js/.config-db/devices/0x0148/cometz_700.json

172 lines
3 KiB
JSON
Raw Permalink Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Eurotronics",
"manufacturerId": "0x0148",
"label": "Comet Z",
"description": "Radiator Thermostat",
"devices": [
{
// 700 series
"productType": "0x0004",
"productId": "0x0003"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 1,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"label": "Invert LCD",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Normal",
"value": 0
},
{
"label": "Mirrored",
"value": 1
}
]
},
{
"#": "2",
"label": "LCD Timeout",
"valueSize": 1,
"unit": "seconds",
"minValue": 5,
"maxValue": 30,
"defaultValue": 5
},
{
"#": "4",
"label": "Battery Status Reporting",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Event-Controlled",
"value": 0
},
{
"label": "Daily",
"value": 1
}
]
},
{
"#": "5",
"label": "Actual-Temperature Reporting",
"valueSize": 1,
"unit": "0.1 °C",
"minValue": 0,
"maxValue": 50,
"defaultValue": 5,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
// Some devices report this param, some don't, may be related to firmware version.
// But even when not reported by the device, it is supported.
"#": "6",
"label": "Valve Opening Report Change Threshold",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 100,
"defaultValue": 0,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "7",
"label": "Open Window Detection",
"valueSize": 1,
"minValue": 0,
"maxValue": 3,
"defaultValue": 1,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "Low sensitivity",
"value": 1
},
{
"label": "Medium sensitivity",
"value": 2
},
{
"label": "High sensitivity",
"value": 3
}
]
},
{
"#": "8",
"label": "Temperature Calibration",
"valueSize": 1,
"unit": "0.1 °C",
"minValue": -50,
"maxValue": 50,
"defaultValue": 0
}
],
"compat": {
"overrideQueries": {
// The device does not report "Manufacturer specific" as a supported thermostat mode
"Thermostat Mode": [
{
"method": "getSupportedModes",
"result": [0, 1, 11, 15, 31], // Off / Heat / Energy heat / Full power / Manufacturer specific
"persistValues": {
"supportedModes": [0, 1, 11, 15, 31]
},
"extendMetadata": {
"thermostatMode": {
"states": {
"0": "Off",
"1": "Heat",
"11": "Energy heat",
"15": "Full power",
"31": "Manufacturer specific"
}
}
}
}
]
},
"commandClasses": {
"remove": {
"Supervision": {
"endpoints": "*"
}
}
}
},
"metadata": {
"manual": "https://eurotronic.org/wp-content/uploads/2023/04/Comet-Z-Wave-EN-2023-04-06.pdf"
}
}