{ "manufacturer": "Eurotronics", "manufacturerId": "0x0148", "label": "Comet Z", "description": "Radiator Thermostat", "devices": [ { // 700 series "productType": "0x0004", "productId": "0x0003" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Invert LCD", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Normal", "value": 0 }, { "label": "Mirrored", "value": 1 } ] }, { "#": "2", "label": "LCD Timeout", "valueSize": 1, "unit": "seconds", "minValue": 5, "maxValue": 30, "defaultValue": 5 }, { "#": "4", "label": "Battery Status Reporting", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Event-Controlled", "value": 0 }, { "label": "Daily", "value": 1 } ] }, { "#": "5", "label": "Actual-Temperature Reporting", "valueSize": 1, "unit": "0.1 °C", "minValue": 0, "maxValue": 50, "defaultValue": 5, "options": [ { "label": "Disabled", "value": 0 } ] }, { // Some devices report this param, some don't, may be related to firmware version. // But even when not reported by the device, it is supported. "#": "6", "label": "Valve Opening Report Change Threshold", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 0, "options": [ { "label": "Disabled", "value": 0 } ] }, { "#": "7", "label": "Open Window Detection", "valueSize": 1, "minValue": 0, "maxValue": 3, "defaultValue": 1, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Low sensitivity", "value": 1 }, { "label": "Medium sensitivity", "value": 2 }, { "label": "High sensitivity", "value": 3 } ] }, { "#": "8", "label": "Temperature Calibration", "valueSize": 1, "unit": "0.1 °C", "minValue": -50, "maxValue": 50, "defaultValue": 0 } ], "compat": { "overrideQueries": { // The device does not report "Manufacturer specific" as a supported thermostat mode "Thermostat Mode": [ { "method": "getSupportedModes", "result": [0, 1, 11, 15, 31], // Off / Heat / Energy heat / Full power / Manufacturer specific "persistValues": { "supportedModes": [0, 1, 11, 15, 31] }, "extendMetadata": { "thermostatMode": { "states": { "0": "Off", "1": "Heat", "11": "Energy heat", "15": "Full power", "31": "Manufacturer specific" } } } } ] }, "commandClasses": { "remove": { "Supervision": { "endpoints": "*" } } } }, "metadata": { "manual": "https://eurotronic.org/wp-content/uploads/2023/04/Comet-Z-Wave-EN-2023-04-06.pdf" } }