"manufacturer": "Fibargroup",
"manufacturerId": "0x010f",
"label": "FGBS001",
"description": "Universal Binary Sensor",
"devices": [
{
"productType": "0x0501",
"productId": "0x0102"
},
{
"productType": "0x0501",
"productId": "0x0109"
},
{
"productType": "0x0501",
"productId": "0x1002"
},
{
"productType": "0x0501",
"productId": "0x2002"
},
{
"productType": "0x0501",
"productId": "0x3002"
},
{
"productType": "0x0501",
"productId": "0x4002"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Input 1",
"maxNodes": 5
},
"2": {
"label": "Input 2",
"maxNodes": 5
},
"3": {
"label": "Controller Updates",
"description": "Reports on the condition of the device",
"maxNodes": 1,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"label": "Input I Alarm Cancellation Delay",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0,
"unsigned": true
},
{
"#": "2",
"label": "Input 2 Alarm Cancellation Delay",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0,
"unsigned": true
},
{
"#": "3",
"label": "Type of Input No. 1",
"description": "Type of input no. 1, what the input 1 will report if no contact is made",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "NO (Normal open)",
"value": 0
},
{
"label": "NC (Normal close)",
"value": 1
},
{
"label": "Monostable",
"value": 2
},
{
"label": "Bistable",
"value": 3
}
]
},
{
"#": "4",
"label": "Type of Input No. 2",
"description": "Type of input no. 2, what the input 2 will report if no contact is made",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "NO (Normal open)",
"value": 0
},
{
"label": "NC (Normal close)",
"value": 1
},
{
"label": "Monostable",
"value": 2
},
{
"label": "Bistable",
"value": 3
}
]
},
{
"#": "5",
"label": "Type of Control Frame for Association Group 1",
"valueSize": 1,
"defaultValue": 255,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Alarm generic",
"value": 0
},
{
"label": "Alarm smoke",
"value": 1
},
{
"label": "Alarm CO",
"value": 2
},
{
"label": "Alarm CO2",
"value": 3
},
{
"label": "Alarm heat",
"value": 4
},
{
"label": "Alarm water",
"value": 5
},
{
"label": "Basic Set",
"value": 255
}
]
},
{
"#": "6",
"label": "Type of Control Frame for Association Group 2",
"valueSize": 1,
"defaultValue": 255,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Alarm generic",
"value": 0
},
{
"label": "Alarm smoke",
"value": 1
},
{
"label": "Alarm CO",
"value": 2
},
{
"label": "Alarm CO2",
"value": 3
},
{
"label": "Alarm heat",
"value": 4
},
{
"label": "Alarm water",
"value": 5
},
{
"label": "Basic Set",
"value": 255
}
]
},
{
"#": "7",
"label": "Forced Level of Dimming Group 1",
"description": "Value of the parameter specifying the forced levels.",
"valueSize": 1,
"minValue": 1,
"maxValue": 255,
"defaultValue": 255,
"unsigned": true
},
{
"#": "8",
"label": "Forced Level of Dimming Group 2",
"description": "Value of the parameter specifying forced levels.",
"valueSize": 1,
"minValue": 1,
"maxValue": 255,
"defaultValue": 255,
"unsigned": true
},
{
"#": "9",
"label": "Deactivate Transmission of Frame Canceling Alarm",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Groups 1 and 2 sent",
"value": 0
},
{
"label": "Only group 1 sent",
"value": 1
},
{
"label": "Only group 2 sent",
"value": 2
}
]
},
{
"#": "10",
"label": "Interval Between Readings of Temperature Sensors",
"valueSize": 1,
"minValue": 1,
"maxValue": 255,
"defaultValue": 20,
"unsigned": true
},
{
"#": "11",
"label": "Temperature Report Interval",
"description": "The forced report is sent immediately after ...",
"valueSize": 1,
"minValue": 1,
"maxValue": 255,
"defaultValue": 200,
"unsigned": true
},
{
"#": "12",
"label": "Temperature Change Report Threshold",
"description": "This is the maximum acceptable difference between",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 8,
"unsigned": true
},
{
"#": "13",
"label": "Transmitting Alarm/control Frame Broadcast Mode",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "IN1 and IN2 broadcast inactive",
"value": 0
},
{
"label": "IN1 mode active, sensor 2 mode inactive",
"value": 1
},
{
"label": "IN1 mode inactive, sensor 2 mode active",
"value": 2
},
{
"label": "IN1 and IN2 broadcast mode active",
"value": 3
}
]
},
{
"#": "14",
"label": "Scene Activation",
"description": "Enable/Disable scene functionality.",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Scenes disabled",
"value": 0
},
{
"label": "Scenes enabled",
"value": 1
}
]
}
],
"compat": {
"mapBasicSet": "auto",
"commandClasses": {
"remove": {
// Alarm Sensor CC is reported as supported, but we either get no response
// or the supported sensor types are incorrectly encoded
"Alarm Sensor": {
"endpoints": "*"
}
}
}
}
}