{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGBS001", "description": "Universal Binary Sensor", "devices": [ { "productType": "0x0501", "productId": "0x0102" }, { "productType": "0x0501", "productId": "0x0109" }, { "productType": "0x0501", "productId": "0x1002" }, { "productType": "0x0501", "productId": "0x2002" }, { "productType": "0x0501", "productId": "0x3002" }, { "productType": "0x0501", "productId": "0x4002" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Input 1", "maxNodes": 5 }, "2": { "label": "Input 2", "maxNodes": 5 }, "3": { "label": "Controller Updates", "description": "Reports on the condition of the device", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Input I Alarm Cancellation Delay", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "2", "label": "Input 2 Alarm Cancellation Delay", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "3", "label": "Type of Input No. 1", "description": "Type of input no. 1, what the input 1 will report if no contact is made", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "NO (Normal open)", "value": 0 }, { "label": "NC (Normal close)", "value": 1 }, { "label": "Monostable", "value": 2 }, { "label": "Bistable", "value": 3 } ] }, { "#": "4", "label": "Type of Input No. 2", "description": "Type of input no. 2, what the input 2 will report if no contact is made", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "NO (Normal open)", "value": 0 }, { "label": "NC (Normal close)", "value": 1 }, { "label": "Monostable", "value": 2 }, { "label": "Bistable", "value": 3 } ] }, { "#": "5", "label": "Type of Control Frame for Association Group 1", "valueSize": 1, "defaultValue": 255, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Alarm generic", "value": 0 }, { "label": "Alarm smoke", "value": 1 }, { "label": "Alarm CO", "value": 2 }, { "label": "Alarm CO2", "value": 3 }, { "label": "Alarm heat", "value": 4 }, { "label": "Alarm water", "value": 5 }, { "label": "Basic Set", "value": 255 } ] }, { "#": "6", "label": "Type of Control Frame for Association Group 2", "valueSize": 1, "defaultValue": 255, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Alarm generic", "value": 0 }, { "label": "Alarm smoke", "value": 1 }, { "label": "Alarm CO", "value": 2 }, { "label": "Alarm CO2", "value": 3 }, { "label": "Alarm heat", "value": 4 }, { "label": "Alarm water", "value": 5 }, { "label": "Basic Set", "value": 255 } ] }, { "#": "7", "label": "Forced Level of Dimming Group 1", "description": "Value of the parameter specifying the forced levels.", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "8", "label": "Forced Level of Dimming Group 2", "description": "Value of the parameter specifying forced levels.", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "9", "label": "Deactivate Transmission of Frame Canceling Alarm", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Groups 1 and 2 sent", "value": 0 }, { "label": "Only group 1 sent", "value": 1 }, { "label": "Only group 2 sent", "value": 2 } ] }, { "#": "10", "label": "Interval Between Readings of Temperature Sensors", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 20, "unsigned": true }, { "#": "11", "label": "Temperature Report Interval", "description": "The forced report is sent immediately after ...", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 200, "unsigned": true }, { "#": "12", "label": "Temperature Change Report Threshold", "description": "This is the maximum acceptable difference between", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 8, "unsigned": true }, { "#": "13", "label": "Transmitting Alarm/control Frame Broadcast Mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "IN1 and IN2 broadcast inactive", "value": 0 }, { "label": "IN1 mode active, sensor 2 mode inactive", "value": 1 }, { "label": "IN1 mode inactive, sensor 2 mode active", "value": 2 }, { "label": "IN1 and IN2 broadcast mode active", "value": 3 } ] }, { "#": "14", "label": "Scene Activation", "description": "Enable/Disable scene functionality.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Scenes disabled", "value": 0 }, { "label": "Scenes enabled", "value": 1 } ] } ], "compat": { "mapBasicSet": "auto", "commandClasses": { "remove": { // Alarm Sensor CC is reported as supported, but we either get no response // or the supported sensor types are incorrectly encoded "Alarm Sensor": { "endpoints": "*" } } } } }