"manufacturer": "Good Way Technology Co., Ltd.",
"manufacturerId": "0x0068",
"label": "TD13010",
"description": "In-Wall Switch",
"devices": [
{
"productType": "0x0003",
"productId": "0x0015",
"zwaveAllianceId": 2948
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "D1 Automatically Turn Off",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "2",
"label": "D2 Automatically Turn Off",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "3",
"label": "Switch Type",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "4",
"label": "Reload Power Status",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "5",
"label": "Power Reporting On Power Change",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 100,
"defaultValue": 10,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "6",
"label": "Watts Auto-Report Period",
"description": "Allowable range: 60-32767",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 300,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "7",
"label": "Kwh Auto-Report Period",
"description": "Allowable range: 60-32767",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 3600,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "8",
"label": "D1 Automatically Turn On",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "9",
"label": "D2 Automatically Turn On",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
}
],
"metadata": {
"inclusion": "Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds",
"exclusion": "Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds",
"reset": "Press the pairing button 3 times in 2 seconds and press and hold the pairing button for more than 5 seconds at the 3rd time.\nThe module is excluded and restores to factory default setting.\nThen the module will be in auto-inclusion mode for 2 minutes.\nPlease use this procedure only when the network primary controller is missing or otherwise inoperable.\n\nThe Device Reset Locally Command Class is used to notify central controllers that a Z-Wave device is resetting its network specific parameters.",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2948/TD13010Z1_Manual_V2.0_20180601.pdf"
}
}