150 lines
3.2 KiB
JSON
150 lines
3.2 KiB
JSON
{
|
|
"manufacturer": "Good Way Technology Co., Ltd.",
|
|
"manufacturerId": "0x0068",
|
|
"label": "TD13010",
|
|
"description": "In-Wall Switch",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0003",
|
|
"productId": "0x0015",
|
|
"zwaveAllianceId": 2948
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "D1 Automatically Turn Off",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "D2 Automatically Turn Off",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Switch Type",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 255,
|
|
"defaultValue": 0,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Reload Power Status",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 255,
|
|
"defaultValue": 0,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "Power Reporting On Power Change",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 10,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Watts Auto-Report Period",
|
|
"description": "Allowable range: 60-32767",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 300,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "7",
|
|
"label": "Kwh Auto-Report Period",
|
|
"description": "Allowable range: 60-32767",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 3600,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "8",
|
|
"label": "D1 Automatically Turn On",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "9",
|
|
"label": "D2 Automatically Turn On",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds",
|
|
"exclusion": "Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds",
|
|
"reset": "Press the pairing button 3 times in 2 seconds and press and hold the pairing button for more than 5 seconds at the 3rd time.\nThe module is excluded and restores to factory default setting.\nThen the module will be in auto-inclusion mode for 2 minutes.\nPlease use this procedure only when the network primary controller is missing or otherwise inoperable.\n\nThe Device Reset Locally Command Class is used to notify central controllers that a Z-Wave device is resetting its network specific parameters.",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2948/TD13010Z1_Manual_V2.0_20180601.pdf"
|
|
}
|
|
}
|