380 lines
7.8 KiB
JSON
380 lines
7.8 KiB
JSON
{
|
|
"manufacturer": "Namron",
|
|
"manufacturerId": "0x0438",
|
|
"label": "4512745",
|
|
"description": "16A Touch Thermostat - Black",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0200",
|
|
"productId": "0xd025"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"associations": {
|
|
"1": {
|
|
"label": "Lifeline",
|
|
"maxNodes": 5,
|
|
"isLifeline": true
|
|
},
|
|
"2": {
|
|
"label": "Heat Set",
|
|
"maxNodes": 5
|
|
}
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "2",
|
|
"label": "Overcurrent Protection",
|
|
"description": "Allowable range: 5-16",
|
|
"valueSize": 1,
|
|
"unit": "A",
|
|
"minValue": 0,
|
|
"maxValue": 16,
|
|
"defaultValue": 16,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Button Vibrations & Sounds",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Low",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "High",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev"
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Overheat Protection",
|
|
"description": "Allowable range: 20-60",
|
|
"valueSize": 1,
|
|
"unit": "°C",
|
|
"minValue": 0,
|
|
"maxValue": 60,
|
|
"defaultValue": 45,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "7",
|
|
"label": "Temperature Control Hysteresis",
|
|
"valueSize": 1,
|
|
"unit": "0.1 °C",
|
|
"minValue": 5,
|
|
"maxValue": 20,
|
|
"defaultValue": 5
|
|
},
|
|
{
|
|
"#": "8",
|
|
"$import": "~/templates/master_template.json#base_enable_disable",
|
|
"label": "Energy Save Mode"
|
|
},
|
|
{
|
|
"#": "9",
|
|
"label": "Temperature Sensor Type",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Ntc/10k b(25/50℃)=3950",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Ntc/15k b(25/50℃)=3950",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Ntc/50k b(25/50℃)=3950",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "Ntc/100k b(25/50℃)=3950",
|
|
"value": 4
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "10",
|
|
"label": "Temperature Control Reference",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Room sensor",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Floor sensor",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Room and floor sensor",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "11",
|
|
"label": "Room Sensor Offset",
|
|
"valueSize": 1,
|
|
"unit": "0.5 °C",
|
|
"minValue": -10,
|
|
"maxValue": 10,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "12",
|
|
"label": "Floor Sensor Offset",
|
|
"valueSize": 1,
|
|
"unit": "0.5 °C",
|
|
"minValue": -10,
|
|
"maxValue": 10,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "13",
|
|
"label": "Drying Mode Duration",
|
|
"valueSize": 1,
|
|
"unit": "minutes",
|
|
"minValue": 5,
|
|
"maxValue": 100,
|
|
"defaultValue": 5
|
|
},
|
|
{
|
|
"#": "14",
|
|
"label": "Mode to Set After Drying Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 2,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Off",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Manual/Comfort",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Auto/Energy saver",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Away",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "16",
|
|
"label": "Automatic Reporting: Temperature Change Threshold",
|
|
"description": "Allowable range: 2-10",
|
|
"valueSize": 1,
|
|
"unit": "0.1 °C",
|
|
"minValue": 0,
|
|
"maxValue": 10,
|
|
"defaultValue": 2,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "17",
|
|
"label": "Automatic Reporting: Humidity Reporting Interval",
|
|
"description": "Allowable range: 30-28800",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 28800,
|
|
"defaultValue": 300,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "18",
|
|
"label": "Automatic Reporting: Power Change Threshold",
|
|
"valueSize": 1,
|
|
"unit": "W",
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 5,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "19",
|
|
"label": "Automatic Reporting: Current Change Threshold",
|
|
"valueSize": 1,
|
|
"unit": "0.1 A",
|
|
"minValue": 0,
|
|
"maxValue": 10,
|
|
"defaultValue": 10,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "20",
|
|
"label": "Automatic Reporting: Voltage Change Threshold",
|
|
"valueSize": 1,
|
|
"unit": "V",
|
|
"minValue": 0,
|
|
"maxValue": 10,
|
|
"defaultValue": 2,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "21",
|
|
"label": "Automatic Reporting: Meter Report Interval",
|
|
"valueSize": 4,
|
|
"unit": "seconds",
|
|
"minValue": 60,
|
|
"maxValue": 2678400,
|
|
"defaultValue": 600
|
|
},
|
|
{
|
|
"#": "22",
|
|
"label": "Display Brightness",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Low",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Medium",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "High",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "23",
|
|
"label": "Home Page Sensor Display",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Indoor air temperature",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "External temperature (Floor temperature)",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "24",
|
|
"label": "Time Zone Differential",
|
|
"description": "Specify the time difference from UTC",
|
|
"valueSize": 1,
|
|
"minValue": -12,
|
|
"maxValue": 12,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "26",
|
|
"label": "Window Open Detection",
|
|
"description": "Specifies the temperature change within three minutes to trigger window open detection",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "1.5 °C",
|
|
"value": 15
|
|
},
|
|
{
|
|
"label": "2.0 °C",
|
|
"value": 20
|
|
},
|
|
{
|
|
"label": "2.5 °C",
|
|
"value": 25
|
|
},
|
|
{
|
|
"label": "3.0 °C",
|
|
"value": 30
|
|
},
|
|
{
|
|
"label": "3.5 °C",
|
|
"value": 35
|
|
},
|
|
{
|
|
"label": "4.0 °C",
|
|
"value": 40
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"compat": {
|
|
// This device gets its timezone information from a different source
|
|
// and correctly expects the time to be set as UTC
|
|
"useUTCInTimeParametersCC": true
|
|
},
|
|
"metadata": {
|
|
"inclusion": "Adding to a Z-Wave Network (Inclusion)\nMethod 1: Select “Add”, then short press button , the device will send out inclusion request, “Status” will show “Inclusion...”. If there is no response from a gateway within 30 seconds, or inclusion failed, “Status” will show “Fail”. If included successfully, “Status” will show “Inclusion OK” and device ID.\nMethod 2: Operate the gateway into inclusion mode, make sure the device is already removed from previous network, reset power of the device, the device will be included to the gateway automatically",
|
|
"exclusion": "Removing from a Z-Wave Network (Exclusion)\nSelect “Remove”, then short press button , the device will send out exclusion request, “Status” will show “Exclusion...”. If there is no response from a gateway within 30 seconds, or exclusion failed, “Status” will show “Fail”. If excluded successfully, “Status” will show “Exclusion OK” and device ID will be showed as 0",
|
|
"reset": "Select “Reset”, then short press button F, the device will start reset, “Status” will show “Reset...”. If there is no response from a gateway within 6 seconds, or exclusion failed, “Status” will show “Fail”. If reset successfully, “Status” will show “Reset OK”",
|
|
"manual": "https://www.elektroimportoren.no/docs/lib/4512745-Brukerveiledning-5.pdf"
|
|
}
|
|
}
|