148 lines
3.6 KiB
JSON
148 lines
3.6 KiB
JSON
{
|
|
"manufacturer": "Aeotec Ltd.",
|
|
"manufacturerId": "0x0371",
|
|
"label": "ZWA019",
|
|
"description": "Water Sensor 7 Pro",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0002",
|
|
"productId": "0x0013",
|
|
"zwaveAllianceId": 3872
|
|
},
|
|
{
|
|
"productType": "0x0102",
|
|
"productId": "0x0013",
|
|
"zwaveAllianceId": 3951
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"associations": {
|
|
"1": {
|
|
"label": "Lifeline",
|
|
"maxNodes": 5,
|
|
"isLifeline": true
|
|
},
|
|
"2": {
|
|
"label": "Water Leakage (Control)",
|
|
"maxNodes": 5
|
|
},
|
|
"3": {
|
|
"label": "Water Leakage (Alarm)",
|
|
"maxNodes": 5
|
|
},
|
|
"4": {
|
|
"label": "Tamper (Alarm)",
|
|
"maxNodes": 5
|
|
}
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "3[0x04]",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#led_indicator_wake"
|
|
},
|
|
{
|
|
"#": "3[0x10]",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#led_indicator_tamper"
|
|
},
|
|
{
|
|
"#": "4",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#range_test_double_click"
|
|
},
|
|
{
|
|
"#": "5",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_trigger"
|
|
},
|
|
{
|
|
"#": "6",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_command_type"
|
|
},
|
|
{
|
|
"#": "7",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_basic_set_on"
|
|
},
|
|
{
|
|
"#": "8",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_basic_set_off"
|
|
},
|
|
{
|
|
"#": "9",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#time_delay_on"
|
|
},
|
|
{
|
|
"#": "10",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#time_delay_off"
|
|
},
|
|
{
|
|
"#": "11",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#time_delay_tamper"
|
|
},
|
|
{
|
|
"#": "12",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#report_on_tamper_cancel"
|
|
},
|
|
{
|
|
"#": "16",
|
|
"label": "Temperature Change Report Trigger",
|
|
"valueSize": 1,
|
|
"unit": "0.1 °(C/F)",
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 20,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "17",
|
|
"label": "Humidity Change Report Trigger",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 20,
|
|
"defaultValue": 5,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "18",
|
|
"label": "Automatic Reporting Interval",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 65535,
|
|
"defaultValue": 43200,
|
|
"unsigned": true,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "64",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#celsius_fahrenheit",
|
|
"valueSize": 1
|
|
},
|
|
{
|
|
"#": "255",
|
|
"$import": "~/0x0086/templates/aeotec_template.json#factory_reset_exclude"
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "1. Open the housing.\n2. Remove the battery protection.\n3. Press the tamper on the side of the appliance three times quickly",
|
|
"exclusion": "1. Open the housing.\n2. Press the tamper on the side of the appliance three times quickly",
|
|
"reset": "This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.\nOnce Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED LED blinks once. Then release tamper and push it again for 5 seconds while the RED LED is blinking until the GREEN LED blinks once",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3872/Water%20Sensor%207%20Pro-3.pdf"
|
|
}
|
|
}
|