"manufacturer": "Aeotec Ltd.",
"manufacturerId": "0x0371",
"label": "ZWA019",
"description": "Water Sensor 7 Pro",
"devices": [
{
"productType": "0x0002",
"productId": "0x0013",
"zwaveAllianceId": 3872
},
{
"productType": "0x0102",
"productId": "0x0013",
"zwaveAllianceId": 3951
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
},
"2": {
"label": "Water Leakage (Control)",
"maxNodes": 5
},
"3": {
"label": "Water Leakage (Alarm)",
"maxNodes": 5
},
"4": {
"label": "Tamper (Alarm)",
"maxNodes": 5
}
},
"paramInformation": [
{
"#": "3[0x04]",
"$import": "~/0x0086/templates/aeotec_template.json#led_indicator_wake"
},
{
"#": "3[0x10]",
"$import": "~/0x0086/templates/aeotec_template.json#led_indicator_tamper"
},
{
"#": "4",
"$import": "~/0x0086/templates/aeotec_template.json#range_test_double_click"
},
{
"#": "5",
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_trigger"
},
{
"#": "6",
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_command_type"
},
{
"#": "7",
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_basic_set_on"
},
{
"#": "8",
"$import": "~/0x0086/templates/aeotec_template.json#association_group_2_basic_set_off"
},
{
"#": "9",
"$import": "~/0x0086/templates/aeotec_template.json#time_delay_on"
},
{
"#": "10",
"$import": "~/0x0086/templates/aeotec_template.json#time_delay_off"
},
{
"#": "11",
"$import": "~/0x0086/templates/aeotec_template.json#time_delay_tamper"
},
{
"#": "12",
"$import": "~/0x0086/templates/aeotec_template.json#report_on_tamper_cancel"
},
{
"#": "16",
"label": "Temperature Change Report Trigger",
"valueSize": 1,
"unit": "0.1 °(C/F)",
"minValue": 0,
"maxValue": 100,
"defaultValue": 20,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "17",
"label": "Humidity Change Report Trigger",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 20,
"defaultValue": 5,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "18",
"label": "Automatic Reporting Interval",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 65535,
"defaultValue": 43200,
"unsigned": true,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "64",
"$import": "~/0x0086/templates/aeotec_template.json#celsius_fahrenheit",
"valueSize": 1
},
{
"#": "255",
"$import": "~/0x0086/templates/aeotec_template.json#factory_reset_exclude"
}
],
"metadata": {
"inclusion": "1. Open the housing.\n2. Remove the battery protection.\n3. Press the tamper on the side of the appliance three times quickly",
"exclusion": "1. Open the housing.\n2. Press the tamper on the side of the appliance three times quickly",
"reset": "This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.\nOnce Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED LED blinks once. Then release tamper and push it again for 5 seconds while the RED LED is blinking until the GREEN LED blinks once",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3872/Water%20Sensor%207%20Pro-3.pdf"
}
}