zwave-js/.config-db/devices/0x0330/zv2400tac-sl-a.json
2025-01-10 22:05:04 -08:00

199 lines
3.5 KiB
JSON

{
"manufacturer": "Sunricher",
"manufacturerId": "0x0330",
"label": "ZV2400TAC-SL-A",
"description": "Knob Smart Dimmer",
"devices": [
{
"productType": "0x0200",
"productId": "0xd010"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "2",
"$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev"
},
{
"#": "3",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Send Basic Report",
"description": "send the basic report to the Lifeline when the load state changed",
"defaultValue": 1
},
{
"#": "4",
"label": "Default Fade Time",
"valueSize": 1,
"defaultValue": 0,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Instantly",
"value": 0
},
{
"label": "1 to 127 seconds",
"value": 1
},
{
"label": "1 to 127 minutes",
"value": 80
},
{
"label": "Factory default duration. (3 second)",
"value": 255
}
]
},
{
"#": "5",
"label": "Minimum Brightness Value",
"valueSize": 1,
"minValue": 0,
"maxValue": 50,
"defaultValue": 0
},
{
"#": "6",
"label": "Maximum Brightness Value",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 100
},
{
"#": "7",
"label": "MOSFET Driving Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Trailing edge",
"value": 0
},
{
"label": "Leading edge",
"value": 1
}
]
},
{
"#": "9",
"label": "Added to and Removed From A Network",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "Enable",
"value": 1
}
]
},
{
"#": "10",
"label": "Detect Load",
"description": "Enable/disable to detect load",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "Enable",
"value": 1
},
{
"label": "Enable to detect only after first re-power",
"value": 2
}
]
},
{
"#": "11",
"label": "Wiring Type",
"valueSize": 1,
"minValue": 0,
"maxValue": 2,
"defaultValue": 0,
"readOnly": true
},
{
"#": "12",
"label": "Load Type",
"valueSize": 1,
"minValue": 0,
"maxValue": 3,
"defaultValue": 0,
"readOnly": true
},
{
"#": "13",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Over Current Protection",
"defaultValue": 1
},
{
"#": "14",
"label": "Threshold, Unit Is W",
"valueSize": 2,
"minValue": 0,
"maxValue": 100,
"defaultValue": 10
},
{
"#": "15",
"label": "Threshold, Unit Is %",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 20
},
{
"#": "21",
"label": "Power Metering Time Cycle",
"valueSize": 4,
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 600
},
{
"#": "22",
"label": "Energy Metering Time Cycle",
"valueSize": 4,
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 1800
},
{
"#": "23",
"label": "Voltage Metering Time Cycle",
"valueSize": 4,
"minValue": 0,
"maxValue": 0,
"defaultValue": 0
},
{
"#": "24",
"label": "Current Metering Time Cycle",
"valueSize": 4,
"minValue": 0,
"maxValue": 0,
"defaultValue": 0
}
]
}